ROTHSCHILD, WI —
OSHA Inspection: ITEL RAIL CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ITEL RAIL CORPORATION in WESTON POWER PLANT NO. 3, ROTHSCHILD, WI 54474 (NAICS 000000). OSHA activity number 106500309.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ITEL RAIL CORPORATION
- Site address
- WESTON POWER PLANT NO. 3
- City
- ROTHSCHILD
- State
- WI
- ZIP
- 54474
- Mailing
- P.O. BOX 9, MOSINEE, WI 54455
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 4789
- Employees
- 3
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 10, 1991
- Abate by
- Jul 15, 1991
- Penalty
- Initial $1,050 · Current $700 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to severe crushing injuries caused by falling or swinging loads released by one or more hoists due to failure of the hoist hook or brake, overloading of the hoist support system, or improper lift coordination during multi-hoist lifts: (a) To lift railroad car bolsters with side frames weighing 7,400 pounds, two chain hoists of one-ton capacity each and one electric hoist of two-ton capacity suspended from an A-frame structure were used. Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow the criteria in ANSI (American National Standards Institute) B30.11, 1973: Monorail Systems and Underhung Cranes. (1) The rated load capacity for the trolley beam and support members must be determined and marked on the structure. (2) Conduct regular monthly inspections with records to determine the condition of the brakes, chains, hooks, top stop limiting device and other components. When any defects are found, the hoist must be taken out of service until repaired. (3) When two or more crane hoists are used to lift a load, assign a qualified responsible person to coordinate the lift so that at no time will any hoist be subject to a load exceeding its rated capacity.
Recent events (2)
- — I (S) $700.00
- — Z (S) $1050.00
1910.184 E01
- Issued
- Jul 10, 1991
- Abate by
- Sep 12, 1991
- Penalty
- Initial $1,050 · Current $700 Reduced
Recent events (2)
- — I (S) $700.00
- — Z (S) $1050.00
1910.184 E03 II
- Issued
- Jul 10, 1991
- Abate by
- Aug 12, 1991
1910.184 E09 II
- Issued
- Jul 10, 1991
- Abate by
- Jul 15, 1991
1910.1200 E01
- Issued
- Jul 10, 1991
- Abate by
- Sep 12, 1991
- Penalty
- Initial $450 · Current $200 Reduced
Recent events (2)
- — I (S) $200.00
- — Z (S) $450.00
1910.1200 H
- Issued
- Jul 10, 1991
- Abate by
- Sep 12, 1991
- Penalty
- Initial $450 · Current $200 Reduced
Recent events (2)
- — I (S) $200.00
- — Z (S) $450.00
1910.141 B01 I
- Issued
- Jul 10, 1991
- Abate by
- Jul 15, 1991
1910.243 B02
- Issued
- Jul 10, 1991
- Abate by
- Aug 9, 1991