OSHA Inspection: AMF ELECTRICAL CONTRACTORS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMF ELECTRICAL CONTRACTORS in 12999 ST. CHARLES ROCK ROAD, BRIDGETON, MO 63044 (NAICS 000000). OSHA activity number 106540446.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AMF Electrical Contractors — free Get an email when a new federal OSHA severe-injury report for AMF Electrical Contractors is published. One employer, no account, unsubscribe in one click.
Site address
12999 ST. CHARLES ROCK ROAD
City
BRIDGETON
State
MO
ZIP
63044
Mailing
1627 SUBLETTE AVENUE P.O.BOX 15158, ST. LOUIS, MO 63110
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
3632
Employees
2000
Ownership type
A
Industry flags
Manufacturing safety.

10 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 05 2 instances 6 exposed
Issued
Dec 8, 1992
Abate by
Jan 11, 1993
Penalty
Initial $3,500 · Current $3,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment and a place of employment which
were free from recognized hazards that were causing or likely to cause
death or serious physical harm to employees in that opeators and
employees working in close proximity to the stacker cranes, were
exposed to the hazard of being crushed by the stacker crane, and its
components due to possible failures caused by inadequate maintenance
and inspections.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is frequent inspections of the crane and crane
rails.
While ultimate responsibility for correcting the hazards rests with
the employer, given his superior knowledge of the operation, one
feasible and acceptable method to be taken by the employer to correct
these hazards would be to comply with either the manufacturer's
recommendations
or the American National Standard for stacker cranes ANSI
B30.18-1987, which requires the employer to do the following:
1.  Prior to initial use, all new, extensively repaired and altered
equipment shall be tested by or under the direction of an appointed
person and a written report furnished by such person, confirming
the load rating system.  These test reports shall be placed on file
where they are readily available to appointed personnel.
2.  Mark the rated load capacity of the stacker crane and it's load
center location, which would be obtained from the manufacturer.
3.  Conduct periodic inspections from one to twelve month intervals
for the following conditions:
a.  Loose bolts and rivets.
b.  Deformed, cracked, or corroded structural members.
c.  Cracked or worn shelves.
d.  Worn, cracked, or distorted parts such as pins, bearings,
wheels, shafts, gears, rollers, clamping devices, bumpers,
switch baffles, interlock bolts and trolley stops.
e.  Wear on brake system parts, linings, pawls and ratches.
f.  Wear of chain sprockets and stretch of chain.
g.  Electrical apparatus for signs or pitting or deterioration of
stations.
h.  Wear on lower load carrying flange of all track sections.
4.  Conduct frequent inspections from a daily to one month interval
for the follow conditions
a.  All functional operating mechanisms for maladjustment
interfering
with proper operations.  Daily.
b.  All functional operating mechanisms for excessive wear of
components.  Daily.
c.  All safety devices for malfunctioning.  Daily.
d.  All hoists and travel limit switches should be checked without
a load on the device at the beginning of each work shift.  Each
motion.
e.  Deterioration or leakage in lines, tanks, valves, drain pumps
or other parts of air or hydraulic systems.  Daily.
f.  Operation of devices to minimize free fall.
g.  Operation of interlock on cab door.
5.  Any hazardous conditions disclosed by the inspection shall be
corrected before normal operation of the stacker crane is resumed.
Recent events (2)
  • — I (S) $3500.00
  • — Z (S) $3500.00

1910.157 C04

Other-than-serious Gravity 01 1 instance 6 exposed
Issued
Dec 8, 1992
Abate by
Dec 14, 1992
Penalty
Initial $1,500 · Current $100 Reduced
Recent events (2)
  • — I (O) $100.00
  • — Z (S) $1500.00

1910.212 A01

Deleted Serious Gravity 01 1 instance 3 exposed
Issued
Dec 8, 1992
Abate by
Jan 11, 1993
Penalty
Initial $1,500 · Current $1,500
Recent events (2)
  • — I (S) $1500.00
  • — Z (S) $1500.00

1910.212 A03 II

Serious Gravity 03 1 instance 3 exposed
Issued
Dec 8, 1992
Abate by
Dec 7, 1993
Penalty
Initial $2,500 · Current $2,500
Recent events (2)
  • — I (S) $2500.00
  • — Z (S) $2500.00

1910.212 A05

Other-than-serious Gravity 01 1 instance 12 exposed
Issued
Dec 8, 1992
Abate by
Jan 11, 1993
Penalty
Initial $1,500
Recent events (2)
  • — I (O)
  • — Z (S) $1500.00

1910.215 A04

Serious Gravity 01 1 instance 1 exposed
Issued
Dec 8, 1992
Abate by
Jan 11, 1993
Penalty
Initial $1,500 · Current $1,500
Recent events (2)
  • — I (S) $1500.00
  • — Z (S) $1500.00

1910.215 B09

Serious Gravity 01 1 instance 1 exposed
Issued
Dec 8, 1992
Abate by
Jan 11, 1993
Penalty
Initial $1,500 · Current $1,500
Recent events (2)
  • — I (S) $1500.00
  • — Z (S) $1500.00

1910.334 A03 III

Other-than-serious Gravity 01 1 instance 6 exposed
Issued
Dec 8, 1992
Abate by
Dec 11, 1992
Penalty
Initial $1,500
Recent events (2)
  • — I (O)
  • — Z (S) $1500.00

1904.5 C

Other-than-serious Gravity 01 1 instance 100 exposed
Issued
Dec 8, 1992
Abate by
Dec 11, 1992
Recent events (2)
  • — I (O)
  • — Z (O)

1910.334 A04

Other-than-serious Gravity 01 2 instances 100 exposed
Issued
Dec 8, 1992
Abate by
Dec 21, 1992
Recent events (2)
  • — I (O)
  • — Z (O)

View AMF Electrical Contractors's full OSHA safety record →