HARTFORD, IL —
OSHA Inspection: CHEMETCO INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CHEMETCO INC. in 101 OLDENBURG ROAD, HARTFORD, IL 62048 (NAICS 000000). OSHA activity number 106551286.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CHEMETCO INC.
- Site address
- 101 OLDENBURG ROAD
- City
- HARTFORD
- State
- IL
- ZIP
- 62048
- Mailing
- P.O. BOX 67, HARTFORD, IL 62048
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3341
- Employees
- 130
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jan 13, 1995
- Abate by
- Jan 19, 1995
- Penalty
- Initial $49,500 · Current $3,500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: ...the hazards of rapidly expanding steam vapor/molten metal explosion. Employees working in the foundry especially in the vicinity of furnaces #1,#2, and #4, were exposed to the hazard of an explosion because pools of water were allowed to accumulate beneath these furnaces. Molten metal accidentally spilling during the charging or any accidental spill of molten metal could entrap the water thereby causing an explosion. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS ... 1. Repair of water leaks in pollution control system that may contribute to water under the furnaces. 2. Curb or otherwise seal a perimeter around the furnaces so that when water spills or otherwise enters the building it cannot collect under the furnaces. DISCLAIMER: 1. You are not limited to the abatement methods suggested above. 2. The methods explained are general and may not be effective in all cases. 3. The employer is responsible for selecting and carrying out an appropriate abatement method.
Recent events (2)
- — F (W) $3500.00
- — Z (W) $49500.00
More inspections at Chemetco INC.
View Chemetco INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 106551286.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.