CAHOKIA, IL —
OSHA Inspection: PARKS COLLEGE OF ST. LOUIS UNIVERSITY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PARKS COLLEGE OF ST. LOUIS UNIVERSITY in 500 FALLING SPRINGS ROAD, CAHOKIA, IL 62206 (NAICS 000000). OSHA activity number 106556756.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PARKS COLLEGE OF ST. LOUIS UNIVERSITY
- Site address
- 500 FALLING SPRINGS ROAD
- City
- CAHOKIA
- State
- IL
- ZIP
- 62206
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 8221
- Employees
- 200
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 29, 1993
- Abate by
- Jul 1, 1993
- Penalty
- Initial $2,250 · Current $1,148 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: ..... the hazards of asphyxiation, steam burn, respiratory disorders, and death. The employer failed to provide employees involved in confined space entry of two tunnels an adequate confined space entry procedure to protect employees from physical hazards, possible overexposure to toxic substances, and/or oxygen deficient atmospheres while performing routine inspection and repair of piping. Among other methods, a feasible and acceptable abatement method to correct the hazards should follow the procedures set forth in the American National Standards Institute ANSI Z117.1-1977, 'Safety Requirements for Working in Tanks and Other Confined Spaces', and should include the following: 1. Implementation of a formal confined space entry program. The program should include the following areas: a) Establishment of a permit system. Entry into a confined space shall be by permit ONLY. The supervisor or a qualified person shall be responsible for securing the permit and both shall sign off when the area has been reviewed and necessary actions confirmed. The permit shall include: location and description of the work to be done, hazards that may be encountered,, complete isolation of the confined space (blanking and/or disconnecting, electrical and mechanical lockout), protective equipment and clothing required, atmospheric test readings, standby person, emergency procedures and the location of first aid equipment. The permit shall be dated and carry an expiration time that will be valid for ONLY ONE SHIFT. b) Establishment of a training program which includes the following areas: emergency entry and exit procedures, use of applicable respirators, first aid, lockout procedures, safety equipment use, rescue and training drills, permit system, and work practices. Training shall not be considered complete until the employee is judged to have attained an acceptable degree of proficiency for entering and working in confined spaces. c) Mechanical ventilation of the confined space shall be provided prior to entry and continued to provide a safe atmosphere. d) Entry into a confined space shall be prohibited until initial testing of the atmosphere has been done from the outside. The tests performed shall include those for oxygen content, flammability, and toxic materials. Measurements shall be made with instruments calibrated daily according to manufacturer's instructions. Instrument operators shall be trained in the use and care of the instruments. e) All entrances to any confined space shall be posted. f) Lockout and tagout procedures shall be used for any electrical or mechanical equipment to which an employee in a confined space could be exposed. g) Personal protective equipment such as respiratory protection shall be chosen and provided on the basis of testing and monitoring. Users of this equipment shall be trained in its limitations and use. Respiratory protection shall be used in accordance with section 1910.134 of 29 CFR 1910 General Industry Standards. Additional personal protective equipment such as gloves, hard hats, and eye protection shall be chosen when determined to be necessary by a qualified person. h) An individual shall be required to stand by for rescue outside the confined space to be in immediate contact with the employee(s) in the confined space. i) Emergency rescue procedures shall be established with a requirement that the standby person is stationed outside of the confined space with proper equipment to provide for the resuce of the person(s) in the confined space. Such equipment shall include safety harness and lifelines with provisions for hoisting the employee(s) from the confined space. If entry is required for rescue, the rescue employee shall be equipped with approved air supply respiratory protection and other appropriate protective equipment. The standby person shall have some means of alerting others to an emergency situation. DISCLAIMERS: a) The employer is not limited to the abatement methods suggested by OSHA. b) The methods explained are general and may not be effective in all cases. c) The employer is responsible for selecting and carrying out an appropriate abatement method.
Recent events (3)
- — A (S) $1147.50
- — I (S) $1147.50
- — Z (S) $2250.00
1910.212 A05
- Issued
- Mar 29, 1993
- Abate by
- Apr 6, 1993
- Penalty
- Initial $2,250 · Current $1,148 Reduced
Recent events (2)
- — I (S) $1147.50
- — Z (S) $2250.00
1910.1200 E01
- Issued
- Mar 29, 1993
- Abate by
- May 3, 1993
- Penalty
- Initial $1,800 · Current $918 Reduced
Recent events (2)
- — I (S) $918.00
- — Z (S) $1800.00
1910.1200 H
- Issued
- Mar 29, 1993
- Abate by
- May 3, 1993
- Penalty
- Initial $1,800 · Current $918 Reduced
Recent events (2)
- — I (S) $918.00
- — Z (S) $1800.00
1910.38 A02
- Issued
- Mar 29, 1993
- Abate by
- Apr 6, 1993
1910.1200 E01 I
- Issued
- Mar 29, 1993
- Abate by
- May 3, 1993
More inspections at Parks College of ST. Louis University
View Parks College of ST. Louis University's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 106556756.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.