HEIZER, KS ·
OSHA Inspection: NATURAL GAS PIPELINE CO. OF AMERICA
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of NATURAL GAS PIPELINE CO. OF AMERICA in BLACKTOP RD 2 AND 1/2 MILES WEST OF, HEIZER, KS 67530 (NAICS 000000). OSHA activity number 106588072.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATURAL GAS PIPELINE CO. OF AMERICA
- Site address
- BLACKTOP RD 2 AND 1/2 MILES WEST OF
- City
- HEIZER
- State
- KS
- ZIP
- 67530
- Mailing
- RT #4, BOX 65, GREAT BEND, KS 67530
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 4923
- Employees
- 21
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 18, 1995
- Abate by
- Apr 21, 1995
- Penalty
- Initial $1,875 · Current $1,875
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to flying part(s) hazard: (a) On or about November 11, 1994, employees were exposed to being struck by the #1 right jacket water header after it was forced out of it's Dressler coupling pipe joint on the Cooper Bessemer Z330 engine located in Compressor Building #3. This exposure occurred when the head of the #1 right cylinder had been removed and the jacket water system was pressurized to check for leaks. The #1 right cylinder head had served as an anchor for the pipe joint and because of its removal the end of the water header was subject to being forced out of the pipe joint once the system was pressurized. Among other methods, one feasible and acceptable abatement method to correct this hazard is: Ensure cylinder heads are in place when the system is pressurized to check for water leaks in the #1 right and the #2 left cylinders of the Cooper Bessemer Z330 engine, located in Compressor Building #3, or implement equivalent method to ensure pipe joints are anchored.
Recent events (2)
- · I (S) $1875.00
- · Z (S) $1875.00
1910.23 C01
- Issued
- Apr 18, 1995
- Abate by
- May 2, 1995
- Penalty
- Initial $1,500 · Current $1,500
Recent events (2)
- · I (O) $1500.00
- · Z (S) $1500.00
1910.147 C01
- Issued
- Apr 18, 1995
- Abate by
- May 22, 1995
- Penalty
- Initial $1,125 · Current $1,125
Recent events (2)
- · I (O) $1125.00
- · Z (S) $1125.00
1910.147 C04 I
- Issued
- Apr 18, 1995
- Abate by
- May 22, 1995
Recent events (2)
- · I (O)
- · Z (S)
More inspections at Natural GAS Pipeline CO. of America
View Natural GAS Pipeline CO. of America's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in KS
Source