MOORESTOWN, NJ —
OSHA Inspection: 3E GROUP, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of 3E GROUP, INC. in 850 GLEN AVE., MOORESTOWN, NJ 08057 (NAICS 000000). OSHA activity number 106740392.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- 3E GROUP, INC.
- Site address
- 850 GLEN AVE.
- City
- MOORESTOWN
- State
- NJ
- ZIP
- 08057
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3069
- Employees
- 9
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Dec 14, 1995
- Abate by
- Dec 19, 1995
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion hazards: a) Production Area - Reactor #2 - Pressure vessel, being used as a reactor, was not provided with a pressure relief device to prevent over pressurization and vessel failure. On or about 06/16/95. Among other methods, one feasible and acceptable abatement method to correct this hazard is: 1) Follow the requirements of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section VIII, Division I, 1992. 2) Provide pressure vessels with pressure relief devices (protective devices), properly designed and installed prior to initial operation, that meet the requirements of Sections UG-125 through UG-136 of the above code. 3) The relief devices shall be vented to a safe location, preferably to the outside. Such devices shall be inspected and maintained in accordance with the manufacturers recommendations and/or as needed based on what is dictated by the process.