NEW YORK, NY —
OSHA Inspection: MOBIL OIL CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MOBIL OIL CORPORATION in 842 11TH AVE., NEW YORK, NY 10019 (NAICS 000000). OSHA activity number 106866254.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOBIL OIL CORPORATION
- Site address
- 842 11TH AVE.
- City
- NEW YORK
- State
- NY
- ZIP
- 10019
- Mailing
- 888 VETERANS MEMORIAL HWY., HAUPPAUGE, NY 11788
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 5541
- Employees
- 18
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 11, 1996
- Abate by
- Feb 13, 1996
- Penalty
- Initial $4,500 · Current $2,800 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck or crushed by falling auto lift: a)842 11th Ave., New York, N.Y. - The employer failed to ensure that the superstructure bolts on the "Globe" model FS-10 series hydraulic automotive lift were tight and torqued at 125 foot pounds. The employer also failed to perform periodic inspections and establish and implement a preventative maintenance program for the lift; on or about July 12, 1995. ABATEMENT NOTE: Among other methods,one feasible and acceptable means of abatement would be to establish and implement a preventative maintenance program which would include periodic inspection and checking the tightness of superstructure bolts for proper torque as required by the manufacturer and referenced in section 3.1 of the Globe Installation, Operation and Service Part Manual- Model FS-10 Series,and referenced in American National Standard for Automotive Lifts-Safety Requirements for the Construction, Care, and Use - ANSI/ALI B153.1-1990, section 7.3 and Standards for Automotive Lifts - Safety Requirements for Operation, Inspection, and Maintenance (ALI ALOIM-1994) - sections 5.1, 5.6.2.6, and 6.1.1 as published by the American Lift Institute.
Recent events (2)
- — I (S) $2800.00
- — Z (S) $4500.00
1910.1200 G08
- Issued
- Jan 11, 1996
- Abate by
- Jan 24, 1996
1910.1200 H
- Issued
- Jan 11, 1996
- Abate by
- Jan 24, 1996
More inspections at Mobil OIL Corporation
View Mobil OIL Corporation's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 106866254.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.