OSHA Inspection: CROUSE HINDS DIV OF COOPER INDUSTRIES

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of CROUSE HINDS DIV OF COOPER INDUSTRIES in WOLF STREET AND 7TH NORTH STREET, SYRACUSE, NY 13221 (NAICS 000000). OSHA activity number 106901085.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Crouse Hinds DIV of Cooper Industries — free Get an email when a new federal OSHA severe-injury report for Crouse Hinds DIV of Cooper Industries is published. One employer, no account, unsubscribe in one click.
Site address
WOLF STREET AND 7TH NORTH STREET
City
SYRACUSE
State
NY
ZIP
13221
Mailing
PO BOX 4999, SYRACUSE, NY 13221
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3643
Employees
1250
Ownership type
A
Industry flags
Manufacturing safety.

63 citations on file for this inspection.

5(a)(1)

Unclassified Gravity 02 81 instances 100 exposed
Issued
Jul 23, 1999
Abate by
Jan 23, 2000
Penalty
Initial $5,500 · Current $5,500
53.Building# 2 Tool Room, SWO# 2059, CM electric chain hoist:  There
was no load rating on the supporting structure, and the control reel
does not extend to the full length of the rail. Observed on or about 02-
26-99.
54.Building# 2, SWO# 2062, electric chain hoist:  There was no load
rating on the supporting structure. Observed on or about 02-26-99.
55.Building# 50 Tool & Die Repair, SWO# 2120, electric chain hoist:
There was no load rating on the supporting structure, and the pendant
control was missing the button for the down control. Observed on or
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
about 03-03-99.
56.Building# 50 Tube Mill Process, SWO# 2565, Cleveland Tramrail
electric chain hoist:  There was no load rating on the supporting
structure. Observed on or about 03-03-99.
57.Building# 50, SWO# 2087, electric wire rope hoist:  There was no load
rating on the supporting structure, hook latch was missing, and wire
clips on hoist cable were attached backwards. Observed on or about
03-03-99.
58.Sheet Metal Shop, SWO# 2107, electric wire rope hoist:  Load cable
is damaged (kinked), load cable is crossed/overlapped on the drum,
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of being struck by the load should the overhead
hoist, supporting
structure, or below-the-hook lifting devices fail:
a)In the workplace, at locations and equipment identified, on dates
and the hook latch is damaged. Observed on or about 05-18-99.
Abatement certification must be submitted for this item.
Among other methods several feasible and acceptable methods of abatement to
correct each of these hazards are to:
1.Determine load rating from structural design material.
2.Determine loading rating from structural engineering study.
3.Label the proper rating on each of the supporting structures.
4.Establish a log of each hoist for frequent and periodic inspection.
5.Label the controls for the direction of operation.
listed, the
6.Repair/ replace controls.
7.Repair/ replace hook latches.
following overhead hoists had missing and/or damaged hook latches, unrated
supporting structures, unlabeled controls, damaged controls, or damaged
wire rope, including, but not limited to:
1.Aluminum Foundry, SWO# 2477, Cleveland Tramrail electrolift
electric wire rope hoist:  The electric control lines entering/exiting the
pendant control had insulation removed exposing bare wires.
Observed on or about 02-23-99.
2.Iron Foundry, SWO# 2545, pneumatic chain hoist:  The controls were
8.Follow requirements as listed in ASME/ANSI B30.16.
9.  Follow requirements as listed in ANSI B30.11.
10.Replace wire ropes with defects such as severe kinking, etc.
b)In the workplace, at locations and equipment identified, on dates as
indicated, the following below-the-hook lifting devices had no rated load
marking and no initial, frequent or periodic inspections performed,
including,
but not limited to:
1.Coremaking Area:  A Morse lifting device, Serial# 172852, suspended
by SWO# 2547 was not provided with frequent and periodic
inspections. Observed on or about 02-22-99.
2.Shalco Area:  Two lifting devices attached to Gardner Denver Hoists,
were not provided with frequent and periodic inspections. Observed
on or about 05-18-99.
3.Iron Foundry:  Lifting device suspended by SWO# 2504 was not
provided with frequent and periodic inspections and was not provided
with any markings or load ratings. Observed on or about 02-22-99.
4.Iron Foundry:  Lifting device suspended by SWO# 2486, was not
provided with frequent and periodic inspections. Observed on or about
02-22-99.
5.Iron Foundry:  Lifting Device suspended by SWO# 2489, was not
provided with any markings or load ratings, and was not provided
with any frequent or periodic inspections. Observed on or about 02-
22-99.
6.Aluminum Foundry:  Lifting device suspended by Hoist# 12 was not
provided with any markings or load ratings and was not provided with
frequent and periodic inspections. Observed on or about 02-23-99.
7.Aluminum Foundry:  Lifting device suspended by SWO# 2466 was not
provided with any markings or load ratings, and was not provided
with any frequent and periodic inspections. Observed on or about 02-
23-99.
8.Aluminum Foundry:  Lifting device suspended by SWO# 2464 was not
provided with any markings or load ratings, and was not provided
with any frequent and periodic inspections. Observed on or about 02-
23-99.
9.Plastics Department:  Two Barrel lifting devices that are suspended
from SWO# 2083 were not provided with any markings or load
ratings, and were not provided with any frequent or periodic
inspections. Observed on or about 02-24-99.
10.Building# 4:  Lifting device suspended by SWO# 2096 was not
provided with any markings or load ratings, and was not provided
with any frequent or periodic inspections. Observed on or about 02-
26-99.
11.Sheet Metal Department:  Lifting device suspended by SWO# 2018
was not provided with any markings or load ratings, and was not
provided with any frequent or periodic inspections. Observed on or
about 05-18-99.
12.Tank Wash Area:  Lifting device suspended by SWO# 2049 was not
provided with any markings or load ratings, and was not provided
with any frequent or periodic inspections. Observed on or about 02-
26-99.
13.Tank Wash Area:  Lifting device suspended by SWO# 2047 was not
provided with any markings or load ratings, and was not provided
with any frequent or periodic inspections. Observed on or about 02-
26-99.
14.Tank Wash Area:  Lifting device suspended by SWO# 2490 was not
provided with any frequent or periodic inspections. Observed on or
about 02-26-99.
15.Enamel Area:  Lifting device suspended by SWO# 2089 was not
provided with any markings or load ratings, and was not provided
with any frequent or periodic inspections. Observed on or about 02-
26-99.
16.Aluminum Foundry:  Lifting device suspended by SWO# 2469 was not
provided with any markings or load ratings, and was not provided
with any frequent or periodic inspections. Observed on or about 02-
23-99.
17.Aluminum Foundry:  Lifting device suspended by SWO# 2468 was not
provided with any markings or with any frequent or periodic
inspections. Observed on or about 02-23-99.
18.Building# 50 Tube Mill Process:  Lifting device suspended by SWO#
2565 was not provided with any markings or load ratings, and was not
provided with any frequent or periodic inspections.  Observed on or
about 03-03-99.
19.Building# 50 Tool & Die Repair:  Lifting device suspended by SWO#
2120 was not provided with any markings or load ratings, and was not
provided with any frequent or periodic inspections. Observed on or
about 03-03-99.
20.Electric Melt:  Magnetic lifting device suspended by SWO# 1205 was
not provided with any cautionary labeling, markings or load ratings,
and was not provided with any frequent inspections. Observed on or
about 03-04-99.
21.Electric Melt:  Magnetic lifting device suspended by SWO# 1206 was
not provided with any cautionary labeling, markings or load ratings,
and was not provided with any frequent inspections. Observedon or
about 03-04-99.
22.Bin Wash:  Lifting device supported by SWO# 2078 was not provided
with any markings or load ratings, and was not provided with any
frequent or periodic inspections. Observed on or about 02-24-99.
23.Building# 50, Tool & Die Repair:  Lifting device used under various
SWO#'s was not provided with any markings or load ratings, and was
not provided with any frequent or periodic inspections. Observed on
or about 03-03-99.
Abatement certification must be submitted for this item.
Among other methods, several feasible and acceptable abatement methods to
correct
each of these hazards are to:
1.Prior to initial use, all new, modified or repaired lifting devices shall
be inspected by a designated person and an operational test performed
to verify compliance.
2.Mark the rated load capacity of the lifting device on the main
structure or equivalent.
3.Conduct frequent and periodic inspections of the lifting devices for
wear, deterioration or malfunction in accordance with ASME B30.20.
not labeled and there was no load rating on the hoist or the supporting
structure. Observed on or about 02-22-99.
3.Coremaking Area, SWO# 2547, Centurion pneumatic chain hoist:
There was no load rating on the supporting structure. Observed on or
about 02-22-99.
4.Coremaking Area, SWO# 2460, pneumatic chain hoist:  There was no
load rating on the supporting structure. Observed on or about 02-22-
99.
5.Shalco Area, SWO# 2491, hoist:  There was no load rating on the
supporting structure. Observed on or about 02-22-99.
6.Shalco Area:  Two Gardner-Denver Hoists were supported by one
supporting structure that did not have any load rating. Observed on
or about 02-22-99.
7.Iron Foundry, SWO# 2532, electric wire rope hoist:  There was no
load rating on the hoist or the supporting structure. Observed on or
about 02-22-99.
8.Iron Foundry, SWO# 1404, electric wire rope hoist:  There was no
load rating on the supporting structure. Observed on or about 02-22-
99.
9.Iron Foundry:  SWO#'s 2487, 2528, and 2504 were all attached to the
same supporting structure that did not have any load rating. Observed
on or about 02-22-99.
10. Iron Foundry, floor molding area:  An electric chain hoist had no load
rating on the structure, no directional labels on the controls, and no
hook latch. Observed on or about 02-22-99.
11.Iron Foundry, SWO# 2486, pneumatic chain hoist:  There was no load
rating on the supporting structure. Observed on or about 02-22-99.
12.Iron Foundry, SWO# 2489, pneumatic chain hoist:  There was no load
rating on the supporting structure. Observed on or about 02-22-99.
13.Foundry Maintenance, welding area, SWO# 2093, Yale electric wire
rope hoist:  There was no load rating on the supporting structure and
the wire rope was overlapped onto itself on the drum. Observed on or
about 02-22-99.
14.Foundry maintenance, pneumatic chain hoist:  There was no load
rating on the support structure. Observed on or about 02-22-99.
15. Iron Foundry, SWO# 2531, electric wire rope hoist:  There were no
load rating on the supporting structure or the hoist. Observed on or
about 02-22-99.
16.Iron Foundry: SWO#'s 2531, 2537, 2539, 2538, electric wire rope
hoists, were on the same supporting structure (SWO# 2404), which did
not have any load rating. Observed on or about 02-22-99.
17.Aluminum Foundry, Hoist #12, pneumatic chain hoist:  There was no
load rating on the supporting structure and the hook latch was
broken. Observed on or about 02-23-99.
18.Aluminum Foundry, SWO# 2465, electric wire rope hoist:  The
controls were not labeled and there was no load rating on the
supporting structure. Observed on or about 02-23-99.
19.Aluminum Foundry, SWO# 2466, Cleveland tramrail, electric chain
hoist:  The controls were not labeled. Observed on or about 02-23-99.
20.Aluminum Foundry, SWO# 2464, hoist:  The controls were not
labeled. Observed on or about 02-23-99.
21.Aluminum Foundry: SWO#'s 2466, 2465, 2464, 2467, were all on the
same supporting structure which was not labeled with a load rating.
Observed on or about 02-23-99.
22.Aluminum Foundry, SWO# 2469, electric wire rope hoist:  Controls
were not labeled, no load rating for the supporting structure.
Observed on or about 02-23-99.
23.Aluminum Foundry, SWO# 2468, electric wire rope hoist:  Controls
were not labeled, no load rating for the supporting structure.
Observed on or about 02-23-99.
24.Building 33:  The CM Lodestar electric chain hoist in front of the
powder paint area was attached to a support structure that was not
provided with a load rating. Observed on or about 02-24-99.
25.Plastics Department, SWO# 2083, Yale pneumatic chain hoist:  The
controls were not labeled, and the supporting structure was not
labeled with the load ratings. Observed on or about 02-24-99.
26.Bin Wash, SWO# 2078, Yale pneumatic chain hoist:  The controls
were not labeled, there was no load rating for the supporting
structure, and the hook latch was missing. Observed on or about 02-
24-99.
27.Power Plant, SWO# 2482, electric chain hoist:  There was no load
rating for the supporting structure, and there were no labels on the
controls. Observed on or about 02-24-99.
28.Truck Maintenance, SWO# 2074, electric chain hoist:  There was no
load rating on the supporting structure. Observed on or about 02-24-
99.
29.CNC, SWO# 1984, pneumatic chain hoist:  The controls were not
labeled and there was no load rating for the supporting structure.
Observedon or about 02-25-99.
30.Plating Department, pneumatic chain hoist:  There was no load rating
on the supporting structure. Observed on or about 2-26-99.
31.Chip Room, SWO# 2499, electric chain hoist:  There was no load
rating on the supporting structure. Observed on ore about 02-25-99.
32.Building# 2, SWO# 2054, pneumatic chain hoist:  There was no load
rating for the supporting structure. Observed on or about 02-25-99.
33.Building# 2, SWO# 2011, pneumatic chain hoist:  There was no
labeling of the controls, and there was no load rating on the
supporting structure. Observed on or about 02-25-99.
34.Building# 2, SWO# 2008, pneumatic chain hoist:  There was no load
rating for the supporting structure. Observedon or about 02-25-99.
35.Building# 2, SWO# 2507, pneumatic chain hoist:  There was no load
rating for the supporting structure. Observed on or about 02-25-99.
36.Building# 2, SWO# 2567, pneumatic chain hoist:  There was no load
rating for the supporting structure. Observed on or about 02-25-99.
37.Building# 2, SWO# 2029, electric chain hoist:  There was no load
rating for the supporting structure. Observed on or about 02-25-99.
38.Building# 4 cold form, Coffin electric chain hoist:  There was no load
rating or the supporting structure. Observed on or about 02-26-99.
39.Press Room, SWO# 2573, electric chain hoist:  There was no load
rating for the supporting structure. Observed on or about 02-26-99.
40.Press Room, SWO# 2035, electric wire rope hoist:  There was no load
rating for the supporting structure. Observed on or about 02-26-99.
41.Building# 4 press annex, SWO# 2572, pneumatic chain hoist:  There
was no load rating on the supporting structure. Observed on or about
02-26-99.
42.Building# 4, SWO# 2096, pneumatic chain hoist:  The controls were
not labeled and there was no load rating on the supporting structure.
Observed on or about 02-26-99.
43.Sheet Metal, SWO# 2018, electric chain hoist:  Controls were not
labeled, no load rating on the supporting structure, and support rods
were tilted. Observed on or about 05-18-99.
44.Cover Cell Area, SWO# 2571, Budget electric chain hoist:  There was
no load rating on the supporting structure. Observed on or about 02-
26-99.
45.Cover Cell Area, SWO# 2023, electric chain hoist:  There was no load
rating on the supporting structure. Observed on  or about 02-26-99.
46.CA1 Assembly, SWO# 2032, pneumatic chain hoist:  There was no
load rating on the supporting structure. Observed on or about 02-26-
99.
47.CNC Maintenance, SWO# 2558, pneumatic chain hoist:  There was no
load rating on the supporting structure. Observed on or about 02-26-
99.
48.Tank Wash Area, SWO# 2049, pneumatic chain hoist:  The support
structure was not labeled, and the support structure was in disrepair
(connecting pins drifted). Observed on or about 02-26-99.
49.Tank Wash Area, SWO# 2047, pneumatic chain hoist:  Support beams
were not labeled, and supporting structure was in disrepair
(connecting pins drifted). Observed on or about 02-26-99.
50.Tank Wash Area, SWO# 2490, pneumatic wire rope hoist:  Controls
were not labeled, and there was no load rating on the supporting
structure. Observed on or about 02-26-99.
51.Enamel, SWO# 2089, pneumatic chain hoist:  There was no load
rating on the supporting structure, and controls were not legible
(painted over). Observed on or abbout 02-26-99.
52. Building# 2 conveyor from CNC, SWO# 2040, Yale pneumatic chain
hoist:  There was no load rating on the supporting structure.
Observed on or about 02-26-99.

5(a)(1)

Unclassified Gravity 03 2 instances 1 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of being pulled into and crushed by the
rotating parts of a pipe
threading machine.
In the workplace, at locations and equipment identified, on or about
02-22-99, pipe
threading machines were activated by a manually operated on/off switch
that would
not automatically shut the machine off should the operator be
inadvertently caught
in the machine.
a)Iron Foundry, Machine shop, adjacent to welding area, secured area, rigid
pipe threading machine.
b)Bldg #50, Compressor Room, Oster pipe threading machine.
Among other methods, one feasible method to reduce the hazard is to
install a
momentary contact device (deadman foot switch) to control power input to
the
machine.  The device would automatically stop the machine and the rotating
parts
if the operators foot was removed from the switch for any reason.  The
foot switch
must be provided with a protective cover as described in 29 CFR
1910.217(b)(4).

1904.2 A

Unclassified Gravity 00 5 instances
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.22 A02

Unclassified Gravity 01 2 instances 2 exposed
Issued
Jul 23, 1999
Abate by
Aug 23, 1999
Penalty
Initial $5,500 · Current $5,500

1910.22 D01

Unclassified Gravity 01 2 instances 2 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.23 C01

Unclassified Gravity 10 10 instances 8 exposed
Issued
Jul 23, 1999
Abate by
Aug 23, 1999
Penalty
Initial $5,500 · Current $5,500

1910.23 C03

Unclassified Gravity 10 1 instance 1 exposed
Issued
Jul 23, 1999
Abate by
Sep 23, 1999
Penalty
Initial $5,500 · Current $5,500

1910.36 B06

Unclassified Gravity 01 1 instance 1 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.37 Q01

Unclassified Gravity 01 1 instance 1 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $4,000 · Current $4,000

1910.106 E09 III

Unclassified Gravity 02 3 instances 4 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.138 A

Unclassified Gravity 05 1 instance 2 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.146 C02

Unclassified Gravity 10 6 instances 7 exposed
Issued
Jul 23, 1999
Abate by
Sep 1, 1999
Penalty
Initial $5,500 · Current $5,500

1910.146 C03

Unclassified Gravity 10 1 instance 7 exposed
Issued
Jul 23, 1999
Abate by
Aug 23, 1999
Penalty
Initial $5,500 · Current $5,500

1910.146 C07 III

Unclassified Gravity 10 6 instances 7 exposed
Issued
Jul 23, 1999
Abate by
Aug 23, 1999
Penalty
Initial $5,500 · Current $5,500

1910.146 G01

Unclassified Gravity 10 6 instances 7 exposed
Issued
Jul 23, 1999
Abate by
Aug 23, 1999
Penalty
Initial $5,500 · Current $5,500

1910.147 C04 I

Unclassified Gravity 10 7 instances 8 exposed
Issued
Jul 23, 1999
Abate by
Aug 23, 1999
Penalty
Initial $5,500 · Current $5,500

1910.147 C04 II

Unclassified Gravity 10 7 instances 5 exposed
Issued
Jul 23, 1999
Abate by
Aug 23, 1999
Penalty
Initial $5,500 · Current $5,500

1910.147 C05 IID

Unclassified Gravity 01 2 instances 2 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $4,000 · Current $4,000

1910.147 C06 I

Unclassified Gravity 10 1 instance 15 exposed
Issued
Jul 23, 1999
Abate by
Jul 23, 2000
Penalty
Initial $5,500 · Current $5,500

1910.147 C07 I

Unclassified Gravity 10 1 instance 4 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.147 E03

Unclassified Gravity 03 2 instances 2 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.147 F03 I

Unclassified Gravity 10 4 instances 5 exposed
Issued
Jul 23, 1999
Abate by
Aug 23, 1999
Penalty
Initial $5,500 · Current $5,500

1910.147 F03 II

Unclassified Gravity 10 4 instances 4 exposed
Issued
Jul 23, 1999
Abate by
Aug 23, 1999
Penalty
Initial $5,500 · Current $5,500

1910.157 C01

Unclassified Gravity 01 2 instances 2 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $4,000 · Current $4,000

1910.178 M03

Unclassified Gravity 01 1 instance 2 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.179 C02

Unclassified Gravity 03 1 instance 5 exposed
Issued
Jul 23, 1999
Abate by
Oct 23, 1999
Penalty
Initial $5,500 · Current $5,500

1910.179 D03

Unclassified Gravity 03 1 instance 5 exposed
Issued
Jul 23, 1999
Abate by
Oct 23, 1999
Penalty
Initial $5,500 · Current $5,500

1910.179 G01

Unclassified Gravity 01 2 instances 2 exposed
Issued
Jul 23, 1999
Abate by
Aug 23, 1999
Penalty
Initial $5,500 · Current $5,500

1910.179 J02

Unclassified Gravity 03 2 instances 1 exposed
Issued
Jul 23, 1999
Abate by
Oct 25, 1999
Penalty
Initial $5,500 · Current $5,500

1910.179 J03

Unclassified Gravity 03 2 instances 1 exposed
Issued
Jul 23, 1999
Abate by
Oct 25, 1999
Penalty
Initial $5,500 · Current $5,500

1910.179 M01

Unclassified Gravity 03 2 instances 1 exposed
Issued
Jul 23, 1999
Abate by
Aug 23, 1999
Penalty
Initial $5,500 · Current $5,500

1910.184 C01

Unclassified Gravity 03 2 instances 2 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.184 D

Unclassified Gravity 03 1 instance 1 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.212 A01

Unclassified Gravity 10 61 instances 37 exposed
Issued
Jul 23, 1999
Abate by
Oct 25, 1999
Penalty
Initial $5,500 · Current $5,500

1910.212 A03 II

Unclassified Gravity 10 19 instances 14 exposed
Issued
Jul 23, 1999
Abate by
Feb 1, 2000
Penalty
Initial $5,500 · Current $5,500
Recent events (2)
  • — P (U) $5500.00
  • — Z (U) $5500.00

1910.212 A04

Unclassified Gravity 02 1 instance 1 exposed
Issued
Jul 23, 1999
Abate by
Oct 25, 1999
Penalty
Initial $5,500 · Current $5,500

1910.212 A05

Unclassified Gravity 01 2 instances 2 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.212 B

Unclassified Gravity 01 5 instances 5 exposed
Issued
Jul 23, 1999
Abate by
Sep 23, 1999
Penalty
Initial $5,500 · Current $5,500

1910.213 C02

Unclassified Gravity 02 1 instance 1 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.213 H01

Unclassified Gravity 02 1 instance 1 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.215 A04

Unclassified Gravity 02 1 instance 2 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.215 B09

Unclassified Gravity 02 10 instances 6 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.215 C01

Unclassified Gravity 03 1 instance 1 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.215 D01

Unclassified Gravity 03 1 instance 1 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

5(a)(1)

Unclassified Gravity 03 3 instances 2 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970.  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that: Keys left
in the controls.
At locations and equipment identified, on or about 2/25/99: Mechanical
power press
using part revolution clutches and were capable of continuous stroke
functions as the
keys to initiate continuous run were left in the machine for the operator
discretion,
exposing the operator to point of operation hazards.
a)Press room, SWO# 4786, Part Revolution Power Press, Control keys left in
the press.
b)Press room, SWO# 4797, Part Revolution Power Press, control keys left in
the press.
c)Press room, SWO# 4782, Part Revolution Power Press, control keys left in
the press.

1910.217 C03 VIII

Unclassified Gravity 03 1 instance 1 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.219 C04 I

Unclassified Gravity 02 8 instances 5 exposed
Issued
Jul 23, 1999
Abate by
Sep 23, 1999
Penalty
Initial $5,500 · Current $5,500

1910.219 D01

Unclassified Gravity 02 1 instance 1 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.219 E01 I

Unclassified Gravity 02 1 instance 1 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.242 B

Unclassified Gravity 02 8 instances 4 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.252 A02 II

Unclassified Gravity 01 2 instances 3 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $4,000 · Current $4,000

1910.253 B05 III

Unclassified Gravity 02 1 instance 1 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.255 E

Unclassified Gravity 01 3 instances 2 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.303 F

Unclassified Gravity 02 10 instances 2 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.303 G02 I

Unclassified Gravity 02 11 instances 7 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.304 A02

Unclassified Gravity 01 2 instances 2 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.304 E01 IV

Unclassified Gravity 01 3 instances 3 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.304 F05 V

Unclassified Gravity 01 9 instances 4 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.305 B01

Unclassified Gravity 01 3 instances 3 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.305 B02

Unclassified Gravity 01 2 instances 2 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.305 G01 III

Unclassified Gravity 02 7 instances 5 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.305 G02 III

Unclassified Gravity 02 2 instances 2 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $5,500 · Current $5,500

1910.1200 F05 I

Unclassified Gravity 02 6 instances 5 exposed
Issued
Jul 23, 1999
Abate by
Jul 28, 1999
Penalty
Initial $4,000 · Current $4,000

View Crouse Hinds DIV of Cooper Industries's full OSHA safety record →