SELMA, AL —
OSHA Inspection: GLOBE METALLURGICAL INC.
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of GLOBE METALLURGICAL INC. in 2401 OLD MONTGOMERY HWY., SELMA, AL 36703 (NAICS 000000). OSHA activity number 107004020.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GLOBE METALLURGICAL INC.
- Site address
- 2401 OLD MONTGOMERY HWY.
- City
- SELMA
- State
- AL
- ZIP
- 36703
- Mailing
- 2401 OLD MONTGOMERY HWY, SELMA, AL 36703
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3339
- Employees
- 80
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 20, 1991
- Abate by
- Apr 22, 1991
- Penalty
- Initial $1,000 · Current $6,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing of likely to cause death or serious physical harm to employees in that employees were exposed to: a) On or about 9/12/90, employees were exposed to the hazard of fire and/or explosion while engaged in harvesting silicon carbide from an electrical induction furnace. Complete plans of remodeling existing equipment, sequence of operations and specifications were not submitted for approval of the authority having jurisdiction. Among other methods, one feasible and acceptable abatement method to correct this hazard is to have plans drawn and show detail for approval to the authority having jurisdiction, such as the stipulated by National Fire Protection Association, NFPA, Number 86, 1985 Edition, and subsequent updated NFPA 86, Section 1.5 Approval, Plans and Specifications. essential elements for this procedure would include: 1) Have plans drawn and show all essential details as to locations, construction, ventilation, piping and electrical safety equipment. 2) Provide wiring diagrams and sequence of operations for all safety controls. 3) If deviations are made from the referenced standard, special permission is required from authority having jurisdiction. 4) Ensure that all wiring in and around furnaces is in accordance with National Electrical Code, NFPA 70 where it may be required to provide greater safety of the installation under the code, and it shall meet with the approval of all parties having jurisdiction.
Recent events (2)
- — F (S) $6000.00
- — Z (S) $1000.00
5(a)(1)
- Issued
- Mar 20, 1991
- Abate by
- Apr 22, 1991
- Penalty
- Initial $1,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing of likely to cause death or serious physical harm to emloyees in that employees were exposed to: a) On or about 9/12/90, employees were exposed to the hazard of fire and/or explosion while engaged in harvesting silicon carbide from an electrical induction furnace. Employees were not thoroughly trained as to the nature of the hazards and conditions involved in this process. Among other methods, one feasible and acceptable abatement method to correct this hazard is to establish and enforce an adequate training program such as that stipulated by National Fire Protection Association, NFPA, Number 86, 1985 Edition and subsequent updated NFPA 86 Editions; Section 1-6 Operator and Maintenance Personnel Training, essential elements of the training program would include: 1) Thoroughly instruct and train all personnel under supervision of experienced person(s). 2) Reqiure personnel to demonstrate an understanding of the equipment and it's operation to assure knowledge of and practice of safe operating procedures. 3) Establish regular retraining and testing to maintain a high level of proficiency and effectiveness. 4) Provide employees access to operating instructions at all times. 5) Operator training shall include, where applicable, combustion of fuel-air mixtures, expolosion hazards, sources of ignition, functions of control and safety devices, handling of special atmospheres and the handling and processing of hazardous materials. 6) The equipment manufacturer shall provide operating instructions. These shall include: schematic piping and wiring diagrams, start-up procedures, shut down procedures, emergency procedures including those occasioned by loss of special atmospheres, electric power, or other essential utilities and maintenance procedures.
Recent events (2)
- — F (S)
- — Z (S) $1000.00
5(a)(1)
- Issued
- Mar 20, 1991
- Abate by
- Apr 22, 1991
- Penalty
- Initial $1,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) On or about 9/21/90, employees were exposed to the hazard of fire and or explosion while engaged in harvesting silicon carbide from an electrical induction furnace. Employes performing welding on electrical induction furnace and parts thereof, were not certified to perform such work. Among other methods, one feasible and acceptable abatement method to correct this hazard is to have certified welders perform the welding, such as that stipulated by American Welding Society QC3-89.
Recent events (2)
- — F (S)
- — Z (S) $1000.00
5(a)(1)
- Issued
- Mar 20, 1991
- Abate by
- Apr 22, 1991
- Penalty
- Initial $1,000
General-duty citation text
SECTION 5(A)(1) OF THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970: THE EMPLOYER DID NOT FURNISH EMPLOYMENT AND A PLACE OF EMPLOYMENT WHICH WERE FREE FROM RECOGNIZED HAZARDS THAT WERE CAUSING OR LIKELY TO CAUSE DEATH OR SERIOUS PHYSICAL HARM TO EMPLOYEES IN THAT EMPLOYEES WERE EXPOSED TO: A) ON OR ABOUT 9/21/90, EMPLOYEES WERE EXPOSED TO THE HAZARD OF FIRE AND/OR EXPLOSION WHILE ENGAGED IN HARVESTING SILICON CARBIDE FROM AN ELECTRICAL INDUCTION FURNACE. MONITORING WAS NOT PERFORMED FOR CARBON MONOXIDE GAS THAT WAS CREATED BY A MIXTURE OF PULVERIZED COAL AND SILICA. ELECTRICAL INDUCTION FURNACE OPERATING AT A TEMPERATURE OF 2440 DEGREES FAHRENHEIT. CARBON MONOXIDE GAS WILL IGNITE AT A TEMPERATURE OF 1128 DEGREES FAHRENHEIT. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS TO INSTALL SAFETY EQUIPMENT, SUCH AS THAT STIPULATED BY NATIONAL FIRE PROTECTION ASSOCIATION, NFPA, NUMBER 86, 1985 EDITION, AND SUBSEQUENT UPDATE 86 EDITION, CHAPTER 4, SAFETY EQUIPMENT AND APPLICATION WHICH STIPULATES: 1) FOR THE PROTECTION OF PERSONNEL AND PROPERTY, CONSIDERATION SHALL BE GIVEN TO THE SUPERVISION AND/OR MONITORING OF CONDITIONS THAT MAY CAUSE, OR MAY LEAD TO, A REAL OR POTENTIAL HAZARD ON ANY INSTALLATION. 2) ALL SAFETY DEVICES SHALL BE LISTED FOR THE SERVICE INTENDED. SAFETY DEVICES SHALL BE APPLIED AND INSTALLED WITH ESTABLISHED SAFE PRACTICES AND MANUFACTURER'S INSTRUCTIONS. 3) FUEL-FIRED UNITS SHALL BE PROVIDED WITH ALL SAFETY DEVICES IN ACCORDANCE WITH ESTABLISHED SAFE PRACTICES. 4) SAFETY CONSIDERATIONS SHALL EXTEND TO ALLIED EQUIPMENT, AND OTHER PROXIMATE EQUIPMENT, TO AVOID ADDITIONAL CONTRIBUTORY HAZARDS. ABATEMENT OF THIS HAZARD COULD INCLUDE THE INSTALLATION OF SAFETY EQUIPMENT WITH AN AUTOMATIC CARBON MONOXIDE MONITORING SYSTEM, AN AUDIBLE AND VISUAL ALARM DEVICE AND AUTOMATIC SHUT DOWN IN THE EVENT OF POTENTIAL AUTOIGNITION OF COMBUSTIL GAS MIXTURE(S).
Recent events (2)
- — F (S)
- — Z (S) $1000.00
5(a)(1)
- Issued
- Mar 20, 1991
- Abate by
- Apr 22, 1991
- Penalty
- Initial $1,000
General-duty citation text
SECTION 5(A)(1) OF THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970: THE EMPLOYER DID NOT FURNISH EMPLOYMENT AND A PLACE OF EMPLOYMENT WHICH WERE FREE FROM RECOGNIZED HAZARDS THAT WERE CAUSING OR LIKELY TO CAUSE DEATH OR SERIOUS PHYSICAL HARM TO EMPLOYEES IN THAT EMPLOYEES WERE EXPOSED TO: A) ON OR ABOUT 9/21/90, EMPLOYEES ARE EXPOSED TO THE HAZARD OF FIRE AND/OR EXPLOSION WHILE ENGAGED IN HARVESTING SILICON CARBIDE. A WATER TREATMENT SYSTEM WAS NOT IMPLEMENTED TO PREVENT CORROSION OF INTEGRAL PARTS ASSOCIATED WITH THE OPERATION OF AN ELECTRICAL INDUCTION FURNACE. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS TO INSTALL A WATER TREATMENT SYSTEM TO PREVENT CORROSION AND PROVIDE PROPER MAINTENANCE OF SUCH A SYSTEM, SUCH AS THAT STIPULATED BY STANDARD HANDBOOK FOR MECHANICAL ENGINEERS, SEVENTH EDITION, CHAPTER 9. ESSENTIAL ELEMENTS OF A WATER TREATMENT SYSTEM WOULD INCLUDE: 1) REMOVAL OF SUSPENDED SOLIDS. 2) CHEMICAL TREATMENT FOR REMOVAL OF HARDNESS. 3) CATION EXCHANGE FOR REMOVAL OF HARDNESS. 4) DEMINERALIZATION FOR COMPLETE REMOVAL OF DISSOLVED SOLIDS.
Recent events (2)
- — F (S)
- — Z (S) $1000.00
1910.132 A
- Issued
- Mar 20, 1991
- Abate by
- Apr 22, 1991
- Penalty
- Initial $1,000
Recent events (2)
- — F (S)
- — Z (S) $1000.00
More inspections at Globe Metallurgical INC.
View Globe Metallurgical INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 107004020.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.