KETCHIKAN, AK —
OSHA Inspection: MYSTIC WAY, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of MYSTIC WAY, INC. in M/V TRIDENT, KETCHIKAN, AK 99901 (NAICS 000000). OSHA activity number 107105827.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MYSTIC WAY, INC.
- Site address
- M/V TRIDENT
- City
- KETCHIKAN
- State
- AK
- ZIP
- 99901
- Mailing
- 1435 53RD NW, SEATTLE, WA 98107
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2092
- Employees
- 30
- Ownership type
- A
- Industry flags
- Maritime health.
Citations
17 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 16, 1995
- Abate by
- Oct 24, 1995
- Penalty
- Initial $1,250 · Current $1,250
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a recognized hazard of electrical shock or burns: (a)M/V Trident: Employees had occasion to work near five electrical circuit breaker panels boxes with exposed bus bars. Locations included the engine room, machine shop, forepeak, between decks hallway, and aft of Barge I living area. This condition exposed employees to possible electrical shock or burns in the event of accidental contact while flipping switches at the panel box. Among other methods, one feasible and acceptable abatement method to correct this hazard would be to replace the circuit breaker. (b)M/V Trident: Employees had occasion to work near three electrical panelboards located in the cargo hold compressor room. The panelboards were not dead fronted, exposing employees to possible electrical shock or burns in the event of accidental contact with bare electrical conductors. Among other methods, one feasible and acceptable method to correct this hazard would be to replace the missing dead front. (c)M/V Trident: Employees had occasion to work near three unguarded incandescent light bulbs that were less than seven feet high. Two of the light bulbs were located in the freon compressor shack and the third light bulb was in the machine shop. This condition exposed employees to possible electrical shock or burns in the event of contact with bare electrical conductors due to accidental breakage of the light bulbs. Among other methods, one feasible and acceptable abatement method to correct this hazard would be to install guards over the light bulbs. (d)M/V Trident: Employees had occasion to use or work near four electrical outlet boxes with missing cover plates or knockouts. Electrical outlets with missing cover plates were located in the hydraulic pump room, freon compressor shack, and the cargo hold compressor room. An electrical outlet box with a missing knockout was located in the forepeak. This condition exposed employees to possible electrical shock or burns in the event of accidental contact with bare electrical conductors while using the electrical outlets. Among other methods, one feasible and acceptable abatement method to correct this hazard would be to replace the missing cover plates or knockouts. (e)M/V Trident: Employees working in the compressor room had occasion to use or be near an electrical switch box with a missing cover plate. This conditionexposed employees to possible electrical shock or burns in the event of accidental contact with bare electrical conductors when flipping the electrical switch. Among other methods, one feasible and acceptable abatement method to correct this hazard would be to replace the missing cover plate. (f)M/V Trident: Employees had occasion to work near three unguarded double fluorescent light fixtures that were less than seven feet high. Two of the fluorescent light fixtures were located in the compressor room and the third fluorescent light fixture was in the Barge I dayroom. This condition exposed employees to possible electrical shock or burns in the event the light tubes were accidentally broken. Among other methods, one feasible and acceptable abatement method to correct this hazard would be to install guards over the light tubes. (g)M/V Trident: Employees had occasion to work on and maintain electrical panels, refrigeration units, air compressors, and pumps, among other equipment, and were not protected by a lockout/tagout program to control energy sources. This condition exposed employees to possible electrical shock or burns in the event equipment became energized during maintenance operations. Among other methods, one feasible and acceptable abatement method to correct this hazard would be to develop and implement a written lockout/tagout program.
1910.215 A02
- Issued
- Oct 16, 1995
- Abate by
- Oct 24, 1995
- Penalty
- Initial $1,000 · Current $1,000
1910.215 A04
- Issued
- Oct 16, 1995
- Abate by
- Oct 24, 1995
1910.215 B09
- Issued
- Oct 16, 1995
- Abate by
- Oct 24, 1995
1910.1030 C01 I
- Issued
- Oct 16, 1995
- Abate by
- Nov 20, 1995
- Penalty
- Initial $1,250 · Current $1,250
1910.1030 D03 III
- Issued
- Oct 16, 1995
- Abate by
- Oct 24, 1995
1910.1030 F02 I
- Issued
- Oct 16, 1995
- Abate by
- Nov 20, 1995
1910.1030 G02 I
- Issued
- Oct 16, 1995
- Abate by
- Nov 20, 1995
1910.1200 E01
- Issued
- Oct 16, 1995
- Abate by
- Nov 20, 1995
- Penalty
- Initial $750 · Current $750
1910.1200 F05 I
- Issued
- Oct 16, 1995
- Abate by
- Oct 24, 1995
1910.1200 F05 II
- Issued
- Oct 16, 1995
- Abate by
- Oct 24, 1995
1910.1200 G01
- Issued
- Oct 16, 1995
- Abate by
- Nov 20, 1995
1910.1200 H
- Issued
- Oct 16, 1995
- Abate by
- Nov 20, 1995
1918.12 A
- Issued
- Oct 16, 1995
- Abate by
- Nov 20, 1995
- Penalty
- Initial $1,250 · Current $1,250
1904.2 A
- Issued
- Oct 16, 1995
- Abate by
- Nov 20, 1995
1910.134 E03
- Issued
- Oct 16, 1995
- Abate by
- Nov 20, 1995
1910.134 F02 IV
- Issued
- Oct 16, 1995
- Abate by
- Oct 24, 1995
More inspections at Mystic WAY, INC.
View Mystic WAY, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in AK
Source