SEWARD, AK ·
OSHA Inspection: WESTERN SEA INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WESTERN SEA INC in M/V WESTERN SEA-SEWARD HARBOR, NORTH DOCK, SEWARD, AK 99664 (NAICS 000000). OSHA activity number 107107856.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WESTERN SEA INC
- Site address
- M/V WESTERN SEA-SEWARD HARBOR, NORTH DOCK
- City
- SEWARD
- State
- AK
- ZIP
- 99664
- Mailing
- P.O. BOX 3724, FEDERAL WAY, WA 98003
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2092
- Employees
- 29
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
27 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 18, 1990
- Abate by
- Jul 9, 1990
- Penalty
- Initial $300 · Current $300
General-duty citation text
Section 5(a)(1) of the Occupational Safety adn Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a recognized hazard of electrical shock, burns and or electrocution: (a) M/V Western Sea: The breaker box panel labeled GL 2, used to provide power to the state room heaters, located in the galley, was not equipped with a dead front or faceplate. This condition exposed employee(s) to the hazard of contacting live 120/220 volt circuits. Among other methods, a feasible and acceptable abatement method to correct this hazard is to install a dead front or faceplate to prevent employees from contacting the live electrical parts.
Recent events (2)
- · D (S) $300.00
- · Z (S) $300.00
5(a)(1)
- Issued
- Jun 18, 1990
- Abate by
- Jul 23, 1990
- Penalty
- Initial $300 · Current $300
General-duty citation text
Section 5(a)(1) of the Occupational Safety adn Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the recognized hazard of being struck by the descending or ascending elevator, falls into the elevator shaft, crushing injuries,amputations and/or death: a) M/V Western Sea: In the freezer, the elevator to the box storage area was not equipped with a case on the platform to protect employee(s) from falling off the elevator platform and to protect them from the moving elevator chain and from shear points between elevator floors. These doors were not interlocked at the top of the elevator to prevent them from opening when the elevator was not at that level and to protect employee(s) from falling into the elevator shaft. There was no guarding of the bottom of the elevator to protect employee(s) from stepping under it while it was descending. Among other methods, a feasible and acceptable abatement method to correct this hazard is to not allow employee(s) to ride the elevator and provide another access by cutting a hole in the freezer floor and installing a fixed ladder which would be used to access the box storage area. At the top of the elevator either install guardrailing to prevent employee(s) from falling into the ladder way opening, or install a trap door which could be opened and closed as needed to access the fixed ladder. Interlock the doors on the freezer so they can not be opened when the elevator is not a that level and provide guardrails at the base of the elevator to prevent employee(s) from stepping under it while it is descending.
Recent events (2)
- · D (S) $300.00
- · Z (S) $300.00
5(a)(1)
- Issued
- Jun 18, 1990
- Abate by
- Jun 29, 1990
- Penalty
- Initial $200 · Current $200
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to electrocution, electrical shock or burns, and cuts and lacerations due to contact with exposed current carrying parts and broken glass: (a) M/V Western Sea: In the machine shop area, the incandescent light at the top of the stairs, approximately 6 feet, 2 inches above the floor was not equipped with a bulb guard. This condition exposed employee(s) to the hazard of electrocution, shock or burns, and cuts and/or lacerations. (b) M/V Western Sea: In the sewage room adjacent to the gray water tank, the incandescent light located about 6 feet, 2 inches above the floor was not equipped with a bulb guard. This condition exposed employee(s) to the hazard of electrocution, electrical shock or burns, and cuts and/or lacerations. (c) M/V Western Sea: In the aft steering room near the emergency steering motor, the incandescent light, approximately 5 feet, 9 inches above the floor level, was not equipped with a bulb guard. This condition exposed employee(s) to the hazard of electrocution, electrical shock or burns, and cuts and/or lacerations. (d) M/V western Sea. In the engine room, the incandescent lights, 6 feet, 6 inches and 5 feet, 10 inches above the floor were not equipped with bulb guards. This condition exposed employee(s) to the hazard of electrocution, electrical shock or burns, and cuts and/or lacerations. (e) M/V Western Sea: In the lazzerett area, the florescent light 5 feet, 11 inches off the floor was not equipped with a bulb guard. This condition exposed employee(s) to the hazard of electrical shocks or burns, and cuts and/or lacerations. (f) M/V Western Sea: IN the compressor room, the florescent lights located about 6 feet off the floor werenot equipped with a bulb guard. This condition exposed employees to the hazard of electrical shock or burns, and cuts and/or lacerations. (g) M/V Western Sea: In the tool room, the florescent light located over the gasket bench about 5 feet, 11 inches off the floor was not equipped with a bulb guard. This condition exposed employees to the hazard fo electrical shock or burns, cuts, and/or lacerations. Among other methods, one feasible and acceptable abatement method to correct this hazard is to attach bulb guards to lighting fixtures so that the bulbs can not be accidently contacted or broken.
Recent events (2)
- · D (S) $200.00
- · Z (S) $200.00
1910.23 A01
- Issued
- Jun 18, 1990
- Abate by
- Jun 29, 1990
- Penalty
- Initial $300 · Current $300
Recent events (2)
- · D (S) $300.00
- · Z (S) $300.00
1910.23 C01
- Issued
- Jun 18, 1990
- Abate by
- Jul 23, 1990
- Penalty
- Initial $350 · Current $350
Recent events (2)
- · D (S) $350.00
- · Z (S) $350.00
1910.23 C02
- Issued
- Jun 18, 1990
- Abate by
- Jun 29, 1990
- Penalty
- Initial $350 · Current $350
Recent events (2)
- · D (S) $350.00
- · Z (S) $350.00
1910.132 A
- Issued
- Jun 18, 1990
- Abate by
- Jul 9, 1990
- Penalty
- Initial $250 · Current $250
Recent events (2)
- · D (S) $250.00
- · Z (S) $250.00
1910.134 E03
- Issued
- Jun 18, 1990
- Abate by
- Jul 23, 1990
- Penalty
- Initial $640 · Current $640
Recent events (2)
- · D (S) $640.00
- · Z (S) $640.00
1910.134 F02 I
- Issued
- Jun 18, 1990
- Abate by
- Jun 23, 1990
- Penalty
- Initial $350 · Current $350
Recent events (2)
- · D (S) $350.00
- · Z (S) $350.00
1910.134 F05 I
- Issued
- Jun 18, 1990
- Abate by
- Jun 23, 1990
- Penalty
- Initial $250 · Current $250
Recent events (2)
- · D (S) $250.00
- · Z (S) $250.00
1910.147 C01
- Issued
- Jun 18, 1990
- Abate by
- Jul 23, 1990
- Penalty
- Initial $810 · Current $810
Recent events (2)
- · D (S) $810.00
- · Z (S) $810.00
1910.212 A01
- Issued
- Jun 18, 1990
- Abate by
- Jun 23, 1990
- Penalty
- Initial $300 · Current $300
Recent events (2)
- · D (S) $300.00
- · Z (S) $300.00
1910.215 A04
- Issued
- Jun 18, 1990
- Abate by
- Jun 29, 1990
- Penalty
- Initial $200 · Current $200
Recent events (2)
- · D (S) $200.00
- · Z (S) $200.00
1910.215 B09
- Issued
- Jun 18, 1990
- Abate by
- Jun 29, 1990
- Penalty
- Initial $200 · Current $200
Recent events (2)
- · D (S) $200.00
- · Z (S) $200.00
1910.219 D01
- Issued
- Jun 18, 1990
- Abate by
- Jun 29, 1990
- Penalty
- Initial $300 · Current $300
Recent events (2)
- · D (S) $300.00
- · Z (S) $300.00
1910.219 E01 I
- Issued
- Jun 18, 1990
- Abate by
- Jun 29, 1990
Recent events (2)
- · D (S)
- · Z (S)
1910.219 I02
- Issued
- Jun 18, 1990
- Abate by
- Jun 29, 1990
- Penalty
- Initial $250 · Current $250
Recent events (2)
- · D (S) $250.00
- · Z (S) $250.00
1910.1200 E01
- Issued
- Jun 18, 1990
- Abate by
- Jul 23, 1990
- Penalty
- Initial $1,000 · Current $1,000
Recent events (2)
- · D (S) $1000.00
- · Z (S) $1000.00
1910.1200 G01
- Issued
- Jun 18, 1990
- Abate by
- Jul 23, 1990
Recent events (2)
- · D (S)
- · Z (S)
1910.1200 H
- Issued
- Jun 18, 1990
- Abate by
- Jul 23, 1990
Recent events (2)
- · D (S)
- · Z (S)
1918.11 A
- Issued
- Jun 18, 1990
- Abate by
- Jun 23, 1990
- Penalty
- Initial $810 · Current $810
Recent events (2)
- · D (S) $810.00
- · Z (S) $810.00
1918.12 A
- Issued
- Jun 18, 1990
- Abate by
- Jul 23, 1990
- Penalty
- Initial $300 · Current $300
Recent events (2)
- · D (S) $300.00
- · Z (S) $300.00
1918.105 A
- Issued
- Jun 18, 1990
- Abate by
- Jun 23, 1990
- Penalty
- Initial $250 · Current $250
Recent events (2)
- · D (S) $250.00
- · Z (S) $250.00
1903.2 A01
- Issued
- Jun 18, 1990
- Abate by
- Jun 21, 1990
- Penalty
- Initial $100 · Current $100
Recent events (2)
- · D (O) $100.00
- · Z (O) $100.00
1904.2 A
- Issued
- Jun 18, 1990
- Abate by
- Jul 9, 1990
- Penalty
- Initial $200 · Current $200
Recent events (2)
- · D (O) $200.00
- · Z (O) $200.00
1910.151 C
- Issued
- Jun 18, 1990
- Abate by
- Jul 9, 1990
Recent events (2)
- · D (O)
- · Z (O)
1910.252 A02 IVC
- Issued
- Jun 18, 1990
- Abate by
- Jun 25, 1990
Recent events (2)
- · D (O)
- · Z (O)
More inspections in this industry (NAICS 000000)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 107107856.