HOLLSOPPLE, PA —
OSHA Inspection: FIRST MISS STEEL INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of FIRST MISS STEEL INC. in ROUTE 601, P.O. BOX 509, HOLLSOPPLE, PA 15935 (NAICS 000000). OSHA activity number 107150161.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FIRST MISS STEEL INC.
- Site address
- ROUTE 601, P.O. BOX 509
- City
- HOLLSOPPLE
- State
- PA
- ZIP
- 15935
- Mailing
- P.O. BOX 509, HOLLSOPPLE, PA 15935
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3312
- Employees
- 200
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
8 citations on file for this inspection.
1910.132 A
- Issued
- Sep 16, 1994
- Abate by
- Sep 20, 1994
- Penalty
- Initial $3,500 · Current $2,000 Reduced
Recent events (2)
- — I (S) $2000.00
- — Z (S) $3500.00
1910.146 C04
- Issued
- Sep 16, 1994
- Abate by
- Oct 21, 1994
- Penalty
- Initial $2,450 · Current $800 Reduced
Recent events (2)
- — J (U) $800.00
- — Z (S) $2450.00
1910.147 C04 II
- Issued
- Sep 16, 1994
- Abate by
- Nov 15, 1994
- Penalty
- Initial $2,450 · Current $1,200 Reduced
Recent events (2)
- — I (S) $1200.00
- — Z (S) $2450.00
1910.178 L
- Issued
- Sep 16, 1994
- Abate by
- Oct 21, 1994
- Penalty
- Initial $1,750 · Current $1,750
Recent events (2)
- — J (S) $1750.00
- — Z (S) $1750.00
1910.178 P01
- Issued
- Sep 16, 1994
- Abate by
- Sep 26, 1994
- Penalty
- Initial $1,750 · Current $1,200 Reduced
Recent events (2)
- — I (S) $1200.00
- — Z (S) $1750.00
1910.253 E05 I
- Issued
- Sep 16, 1994
- Abate by
- Sep 21, 1994
- Penalty
- Initial $1,400 · Current $1,200 Reduced
Recent events (2)
- — I (S) $1200.00
- — Z (S) $1400.00
1910.253 B05 IIG
- Issued
- Sep 16, 1994
- Abate by
- Sep 21, 1994
- Penalty
- Initial $1,400 · Current $500 Reduced
Recent events (2)
- — J (U) $500.00
- — Z (S) $1400.00
5(a)(1)
- Issued
- Sep 16, 1994
- Abate by
- Oct 4, 1994
- Penalty
- Initial $56,000 · Current $28,000 Reduced
General-duty citation text
Section 5 (a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or were likely to cause death or serious physical harm to employees in that employees were exposed to severe burns due to furnace explosions and molten metal runouts: (a) Melting Department, # 1 Lectromelt Furnace; There were no established procedures developed and/or implemented for the melting, pouring, inspection, and preventative maintenance for the operation of # 1 Lectromelt Furnace. (1) The furnace was being operated with known "hot spots" resulting in furnace shell breakthrough. (2) Safe Job Procedures were not developed to address "hot spots" and the necessary steps/precautions to be taken to prevent furnace blowout. (3) An established campaign life had not been developed and strictly adhered to in order to properly maintain and reline the furnace. Only patching was done in order to prolong furnace operation thereby increasing production. (4) The furnace transformer and taphole have been increased in size (modified) without the manufacturer's approval and/or recommendation. Furthermore, operating and maintenance instructions have not been furnished to include engineering drawings and data. (5) The furnace tilt control panel is not positioned so that the operator has a direct line of site when tapping out the furnace. The control room door blocks the operator's view when in the closed position. (6) Furnace operators were not properly trained so that hazards would be minimized. Operators are tapping out the furnace with known hot spots, charging the furnace beyond it's capacity, charging scrap that has not been analyzed, charging mismarked slugs, and operating the furnace with known water leaks. Among other methods, one feasible and acceptable abatement method to correct this hazard is to develop an operation and preventative maintenance program in accordance with the furnace manufacturer's manuals to insure the correct and proper functioning of all furnace operations. Additionally, written safe job procedures shall be established to address all aspects of furnace operations, particularly the means for emergency cooling of hot spots on the furnace and furnace shutdown for relining.
Recent events (2)
- — J (U) $28000.00
- — Z (W) $56000.00
More inspections at First Miss Steel INC.
View First Miss Steel INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 107150161.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.