Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FIRST MISS STEEL INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of FIRST MISS STEEL INC. in ROUTE 601, P.O. BOX 509, HOLLSOPPLE, PA 15935 (NAICS 000000). OSHA activity number 107150161.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch First Miss Steel INC. — free Get an email when a new federal OSHA severe-injury report for First Miss Steel INC. is published. One employer, no account, unsubscribe in one click.
Site address
ROUTE 601, P.O. BOX 509
City
HOLLSOPPLE
State
PA
ZIP
15935
Mailing
P.O. BOX 509, HOLLSOPPLE, PA 15935
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
3312
Employees
200
Ownership type
A
Industry flags
Manufacturing safety.

8 citations on file for this inspection.

1910.132 A

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 16, 1994
Abate by
Sep 20, 1994
Penalty
Initial $3,500 · Current $2,000 Reduced
Recent events (2)
  • — I (S) $2000.00
  • — Z (S) $3500.00

1910.146 C04

Unclassified Gravity 05 1 instance 4 exposed
Issued
Sep 16, 1994
Abate by
Oct 21, 1994
Penalty
Initial $2,450 · Current $800 Reduced
Recent events (2)
  • — J (U) $800.00
  • — Z (S) $2450.00

1910.147 C04 II

Serious Gravity 05 1 instance 4 exposed
Issued
Sep 16, 1994
Abate by
Nov 15, 1994
Penalty
Initial $2,450 · Current $1,200 Reduced
Recent events (2)
  • — I (S) $1200.00
  • — Z (S) $2450.00

1910.178 L

Deleted Serious Gravity 03 1 instance 1 exposed
Issued
Sep 16, 1994
Abate by
Oct 21, 1994
Penalty
Initial $1,750 · Current $1,750
Recent events (2)
  • — J (S) $1750.00
  • — Z (S) $1750.00

1910.178 P01

Serious Gravity 03 1 instance 2 exposed
Issued
Sep 16, 1994
Abate by
Sep 26, 1994
Penalty
Initial $1,750 · Current $1,200 Reduced
Recent events (2)
  • — I (S) $1200.00
  • — Z (S) $1750.00

1910.253 E05 I

Serious Gravity 02 1 instance 2 exposed
Issued
Sep 16, 1994
Abate by
Sep 21, 1994
Penalty
Initial $1,400 · Current $1,200 Reduced
Recent events (2)
  • — I (S) $1200.00
  • — Z (S) $1400.00

1910.253 B05 IIG

Unclassified Gravity 02 1 instance 2 exposed
Issued
Sep 16, 1994
Abate by
Sep 21, 1994
Penalty
Initial $1,400 · Current $500 Reduced
Recent events (2)
  • — J (U) $500.00
  • — Z (S) $1400.00

5(a)(1)

Unclassified Gravity 10 1 instance 4 exposed
Issued
Sep 16, 1994
Abate by
Oct 4, 1994
Penalty
Initial $56,000 · Current $28,000 Reduced
Section 5 (a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were causing
or were likely to cause death or serious physical harm to employees in
that employees were exposed
to severe burns due to furnace explosions and molten metal runouts:
(a) Melting Department, # 1 Lectromelt Furnace; There were no established
procedures developed
and/or implemented for the melting, pouring, inspection, and preventative
maintenance for the
operation of # 1 Lectromelt Furnace.
(1)  The furnace was being operated with known "hot spots" resulting in
furnace shell       breakthrough.
(2)  Safe Job Procedures were not developed to address "hot spots" and the
necessary steps/precautions to be taken to prevent furnace blowout.
(3)  An established campaign life had not been developed and strictly
adhered to in order to      properly maintain and reline the furnace.
Only patching was done in order to prolong furnace
operation thereby increasing production.
(4)  The furnace transformer and taphole have been increased in size
(modified) without the manufacturer's approval and/or recommendation.
Furthermore, operating and maintenance instructions have not been
furnished to include engineering drawings and data.
(5)  The furnace tilt control panel is not positioned so that the operator
has a direct line of site
when tapping out the furnace.  The control room door blocks the operator's
view when in the
closed position.
(6)  Furnace operators were not properly trained so that hazards would be
minimized.  Operators are tapping out the furnace with known hot spots,
charging the furnace
beyond it's capacity, charging scrap that has not been analyzed, charging
mismarked
slugs, and operating the furnace with known water leaks.
Among other methods, one feasible and acceptable abatement method to
correct
this hazard is to
develop an operation and preventative maintenance program in accordance
with the furnace
manufacturer's manuals to insure the correct and proper functioning of all
furnace operations.
Additionally, written    safe job procedures shall be established to
address all aspects of furnace
operations, particularly the means for emergency cooling of hot spots on
the furnace and furnace
shutdown for relining.
Recent events (2)
  • — J (U) $28000.00
  • — Z (W) $56000.00

View First Miss Steel INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 107150161.