GREENVILLE, GA —
OSHA Inspection: K-TEX APPAREL
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of K-TEX APPAREL in 731 GRIFFIN STREET, GREENVILLE, GA 30222 (NAICS 000000). OSHA activity number 107173510.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- K-TEX APPAREL
- Site address
- 731 GRIFFIN STREET
- City
- GREENVILLE
- State
- GA
- ZIP
- 30222
- Mailing
- PO BOX 245, GREENVILLE, GA 30222
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2311
- Employees
- 55
- Ownership type
- A
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 22, 1993
- Abate by
- Nov 24, 1993
- Penalty
- Initial $1,250 · Current $900 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to danger from overhead PVC pipe carrying compressed air: (a) K-Tex Apparel: Employees are exposed to danger from compressed air inside PVC pipe unrated for that purpose. Among other methods, one feasible and acceptable abatement method to correct this hazard is the complete enclosure of the PVC pipe in a conduit or casing of sufficient strength to provide protection from external damage and deterioration. The replacement of the PVC pipe with a type of pipe approved for the use with compressed air, e.g. ABS (Acrylonitrile-Butadiene-Styrene) and/or other approved piping.
Recent events (2)
- — I (S) $900.00
- — Z (S) $1250.00
1910.147 C01
- Issued
- Oct 22, 1993
- Abate by
- Nov 24, 1993
- Penalty
- Initial $1,000 · Current $200 Reduced
Recent events (2)
- — I (S) $200.00
- — Z (S) $1000.00
1910.303 G02 I
- Issued
- Oct 22, 1993
- Abate by
- Nov 9, 1993
- Penalty
- Initial $1,000 · Current $700 Reduced
Recent events (2)
- — I (S) $700.00
- — Z (S) $1000.00
1910.1200 E01
- Issued
- Oct 22, 1993
- Abate by
- Nov 24, 1993
- Penalty
- Initial $750 · Current $200 Reduced
Recent events (2)
- — I (S) $200.00
- — Z (S) $750.00
1910.1200 F05 I
- Issued
- Oct 22, 1993
- Abate by
- Nov 9, 1993
1910.1200 F05 II
- Issued
- Oct 22, 1993
- Abate by
- Nov 9, 1993
1910.1200 G01
- Issued
- Oct 22, 1993
- Abate by
- Nov 24, 1993
1910.1200 H
- Issued
- Oct 22, 1993
- Abate by
- Nov 24, 1993
1904.2 A
- Issued
- Oct 22, 1993
- Abate by
- Nov 24, 1993
More inspections in this industry (NAICS 000000)