TUCKER, GA ·
OSHA Inspection: CENTURY CLEANING CONTRACTOR
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CENTURY CLEANING CONTRACTOR in 4732 NORTH ATLANTA DRIVE, TUCKER, GA 30084 (NAICS 000000). OSHA activity number 107182529.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CENTURY CLEANING CONTRACTOR
- Site address
- 4732 NORTH ATLANTA DRIVE
- City
- TUCKER
- State
- GA
- ZIP
- 30084
- Mailing
- P.O. BOX 10918, ATLANTA, GA 30310
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 9999
- Employees
- 10
- Ownership type
- A
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- May 18, 1993
- Abate by
- Jun 20, 1993
- Penalty
- Initial $700 · Current $700
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards than were causing of likely to cause death or serious physical harm to employees in that employees are exposed to unknown concentrations of ozone that could potentially exceed concentrations that may produce significant respiratory distress with dyspnea, cyanosis and pulmonary edema. Employees are required to enter the ozone room to place and remove household items and furniture. Some employees have experienced increases of respiratory tract irritations, sinusitis and headaches. On 3-3-93. 0.3 parts per million (ppm) of ozone was measured in the ozone room after the ozone unit was turned off. The detected level exceeded the American Conference of Government Industrial Hygienists (ACGIH) recommended ceiling limit of 0.1 ppm. Employees required to enter the room when the ozone unit is running may be exposed to much higher level of ozone. Among other methods, one feasible and acceptable abatement method to correct this hazard is: 1. Installation of an alarm system to warn the employees when the room has reached levels of ozone that would create an immediately dangerous to life and health (IDLH - 10 ppm) environment. OSHA suggests that the alarm be set up at not higher than 5 ppm. 2. Conduct air monitoring periodically and prior to entering the room. 3. Installation of a timer on the unit that would turn the machine off when desired levels are reached. 4. Relocate the on-off switch to a position outside the decontaminated area. 5. Provide employees with proper respiratory protection.
1910.134 A02
- Issued
- May 18, 1993
- Abate by
- Jun 20, 1993
1910.151 C
- Issued
- May 18, 1993
- Abate by
- Jun 20, 1993
- Penalty
- Initial $525 · Current $525
1910.1200 E01
- Issued
- May 18, 1993
- Abate by
- Jun 20, 1993
- Penalty
- Initial $700 · Current $700
1910.1200 F05 I
- Issued
- May 18, 1993
- Abate by
- Jun 20, 1993
1910.1200 F05 II
- Issued
- May 18, 1993
- Abate by
- Jun 20, 1993
1910.1200 H
- Issued
- May 18, 1993
- Abate by
- Jun 20, 1993
More inspections in this industry (NAICS 000000)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 107182529.