POCATELLO, ID —
OSHA Inspection: UNDER PRESSURE INC.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of UNDER PRESSURE INC. in 1480 WEST BEECHCRAFT, POCATELLO, ID 83204 (NAICS 000000). OSHA activity number 107234791.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNDER PRESSURE INC.
- Site address
- 1480 WEST BEECHCRAFT
- City
- POCATELLO
- State
- ID
- ZIP
- 83204
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 5084
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.303 G01 V
- Issued
- Jun 10, 1993
- Abate by
- Jun 16, 1993
1910.305 B02
- Issued
- Jun 10, 1993
- Abate by
- Jun 16, 1993
5(a)(1)
- Issued
- Jun 9, 1993
- Abate by
- Jul 27, 1993
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential bursting of PVC piping: (a) Shop - Compressed air used to power pneumatic tools, such as grinders, was piped in an above ground 3/4" PVC piping system that was not enclosed in a conduit or casing of sufficient strength to provide protection from external damage and deterioration. Among other methods, one feasible and acceptable abatement method to correct this hazard is replace the PVC piping with a steel pipe system designed for compressed air utilization.
1910.303 G02 I
- Issued
- Jun 9, 1993
- Abate by
- Jun 15, 1993
More inspections at Under Pressure INC.