COTTONWOOD, ID ·
OSHA Inspection: J. C. UHLING PRODUCTS COMPANY
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of J. C. UHLING PRODUCTS COMPANY in 202 EAST MAIN STREET, COTTONWOOD, ID 83522 (NAICS 000000). OSHA activity number 107235582.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J. C. UHLING PRODUCTS COMPANY
- Site address
- 202 EAST MAIN STREET
- City
- COTTONWOOD
- State
- ID
- ZIP
- 83522
- Mailing
- POST OFFICE BOX 445, COTTONWOOD, ID 83522
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3553
- Employees
- 18
- Ownership type
- Private (A)
- Industry flags
- Manufacturing health.
Citations
20 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 3, 1993
- Abate by
- Aug 2, 1995
- Penalty
- Initial $600 · Current $300 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to bursting pipe: (a) Shop Area: Compressed air was piped in an above ground PVC pipe system that was not enclosed in a conduit or casing of sufficient strength to provide protection from external damage and deterioration. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the PVC pipe with a steel pipe system designed for compressed air utilization.
Recent events (3)
- · P (S) $300.00
- · I (S) $300.00
- · Z (S) $600.00
1910.107 B01
- Issued
- Aug 3, 1993
- Abate by
- Sep 20, 1993
- Penalty
- Initial $750 · Current $400 Reduced
Recent events (2)
- · I (S) $400.00
- · Z (S) $750.00
1910.107 B05 I
- Issued
- Aug 3, 1993
- Abate by
- Sep 20, 1993
Recent events (2)
- · I (S)
- · Z (S)
1910.107 B05 IV
- Issued
- Aug 3, 1993
- Abate by
- Oct 31, 1993
Recent events (2)
- · I (S)
- · Z (S)
1910.107 B09
- Issued
- Aug 3, 1993
- Abate by
- Sep 20, 1993
Recent events (2)
- · I (S)
- · Z (S)
1910.107 E02
- Issued
- Aug 3, 1993
- Abate by
- Sep 20, 1993
Recent events (2)
- · I (S)
- · Z (S)
1910.107 G07
- Issued
- Aug 3, 1993
- Abate by
- Aug 9, 1993
Recent events (2)
- · I (S)
- · Z (S)
1910.133 A01
- Issued
- Aug 3, 1993
- Abate by
- Aug 13, 1993
- Penalty
- Initial $750 · Current $400 Reduced
Recent events (2)
- · I (S) $400.00
- · Z (S) $750.00
1910.151 C
- Issued
- Aug 3, 1993
- Abate by
- Aug 13, 1993
Recent events (2)
- · I (S)
- · Z (S)
1910.147 C01
- Issued
- Aug 3, 1993
- Abate by
- Oct 31, 1993
- Penalty
- Initial $750 · Current $400 Reduced
Recent events (2)
- · I (S) $400.00
- · Z (S) $750.00
1910.212 A03 II
- Issued
- Aug 3, 1993
- Abate by
- Aug 6, 1993
- Penalty
- Initial $750 · Current $350 Reduced
Recent events (2)
- · I (S) $350.00
- · Z (S) $750.00
1910.1200 E01
- Issued
- Aug 3, 1993
- Abate by
- Oct 31, 1993
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (2)
- · I (S) $375.00
- · Z (S) $750.00
1910.1200 H
- Issued
- Aug 3, 1993
- Abate by
- Oct 31, 1993
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (2)
- · I (S) $375.00
- · Z (S) $750.00
1904.2 A
- Issued
- Aug 3, 1993
- Abate by
- Sep 20, 1993
Recent events (2)
- · I (O)
- · Z (O)
1910.22 D01
- Issued
- Aug 3, 1993
- Abate by
- Aug 13, 1993
Recent events (2)
- · I (O)
- · Z (O)
1910.134 A02
- Issued
- Aug 3, 1993
- Abate by
- Sep 20, 1993
Recent events (2)
- · I (O)
- · Z (O)
1910.134 B06
- Issued
- Aug 3, 1993
- Abate by
- Sep 20, 1993
Recent events (2)
- · I (O)
- · Z (O)
1910.157 G01
- Issued
- Aug 3, 1993
- Abate by
- Sep 20, 1993
Recent events (2)
- · I (O)
- · Z (O)
1910.303 B02
- Issued
- Aug 3, 1993
- Abate by
- Aug 13, 1993
Recent events (2)
- · I (O)
- · Z (O)
1910.334 A02 II
- Issued
- Aug 3, 1993
- Abate by
- Aug 13, 1993
Recent events (2)
- · I (O)
- · Z (O)
More inspections at J. C. Uhling Products Company