CARLE PLACE, NY —
OSHA Inspection: MONARCH, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of MONARCH, INC. in 440 OLD COUNTRY RD., CARLE PLACE, NY 11514 (NAICS 000000). OSHA activity number 107354730.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MONARCH, INC.
- Site address
- 440 OLD COUNTRY RD.
- City
- CARLE PLACE
- State
- NY
- ZIP
- 11514
- Mailing
- 6 MOUNT BEAR COURT, FARMINGVILLE, NY 11738
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1711
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 12, 1993
- Abate by
- Apr 15, 1993
- Penalty
- Initial $750 · Current $750
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970. The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of being pulled into and crushed by the rotting parts of a pipe threading machine: (a) Atrium, Temerory Floor - Employees were operating a Rigid 300, Serial #742792, pipe threading machine which was activated by a toggle switch that would not automatically shut the machine off if the operator was inadvertently caught up in its rotating parts; on or about 2/17/93. ABATEMENT NOTES: Among other methods, one feasible method to reduce this hazard is to intall a momentary contact device (deadman foot switch) to control power input the machine, as stipulated in American National Standard for portable pipe threading machine (ANSI B208.1-1982).
1903.2 A01
- Issued
- Apr 12, 1993
- Abate by
- Apr 15, 1993
More inspections at Monarch, INC.
View Monarch, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 107354730.