PITTSBURGH, PA —
OSHA Inspection: ANJO CONSTRUCTION COMPANY
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of ANJO CONSTRUCTION COMPANY in G.P.I.A. MIDFIELD TERMINAL PROJECT, P.O. BOX 10332, PITTSBURGH, PA 15231 (NAICS 000000). OSHA activity number 107386120.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANJO CONSTRUCTION COMPANY
- Site address
- G.P.I.A. MIDFIELD TERMINAL PROJECT, P.O. BOX 10332
- City
- PITTSBURGH
- State
- PA
- ZIP
- 15231
- Mailing
- 4540 NEW TEXAS ROAD, PITTSBURGH, PA 15239
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1791
- Employees
- 200
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 29, 1991
- Abate by
- Feb 1, 1991
- Penalty
- Initial $10,000 · Current $1,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death of serious physical harm to employees in that: A) Employees were exposed to being struck by concrete beams, arches, planks, etc. due to structure collapse at the Airside Building at the Greater Pittsburgh International Airport in that the erection sequence developed by the precast element designer was not followed in its entirety by the precast erector.
Recent events (2)
- — F (S) $1000.00
- — Z (W) $10000.00
5(a)(1)
- Issued
- Jan 29, 1991
- Abate by
- Feb 1, 1991
- Penalty
- Initial $10,000 · Current $1,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that: A) Employees were exposed to being struck by building components due to structure collapse at the Airside Building at the Midfield Terminal Project of the Greater Pittsburgh International Airport in that: 1) The roof beam RB-35 at column line B20 failed in flexural due to the inadequate development length of its bottom bars marked #701. 2) The flexural reinforcement of two #7 bars of beam RB-35 to support the construction loads during erection was marginal as per ACI 31B-83. 3) The lap splice length of #7 bars marked #701 and #702 did not meet the ACI design criteria. 4) Four #8 bars for the longitudinal bottom reinforcement of beam RB-35 were not properly spaced by the precast manufacturer. 5) Field examination of the embedded reinforcing steel had indicated a series of inconsistencies in placement of bars.
Recent events (2)
- — F (S) $1000.00
- — Z (W) $10000.00
More inspections at Anjo Construction Company
View Anjo Construction Company's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 107386120.