BOSTON, MA —
OSHA Inspection: U.S. DEPARTMENT OF HEALTH & HUMAN SERVICES
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of U.S. DEPARTMENT OF HEALTH & HUMAN SERVICES in JFK FEDERAL BUILDING, GOVERNMENT CENTER, BOSTON, MA 02109 (NAICS 000000). OSHA activity number 107535718.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. DEPARTMENT OF HEALTH & HUMAN SERVICES
- Site address
- JFK FEDERAL BUILDING, GOVERNMENT CENTER
- City
- BOSTON
- State
- MA
- ZIP
- 02109
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 9431
- Employees
- 400
- Ownership type
- D
Citations
13 citations on file for this inspection.
10201 A
- Issued
- Feb 25, 1992
- Abate by
- Mar 30, 1992
General-duty citation text
Executive Order # 12196, Section # 1-201(a). The head of each agency shall furnish to employees places and conditions of employment that are free from recognized hazards that are causing or are likely to cause death or serious physical harm. The head of the agency did not furnish to employees places and conditions of employment that were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees , in that, on October 4, 1991, the wooden cooling tower located on the roof of the J.F.K. Federal Building, Boston, MA., was not provided with a sprinkler system as required by NFPA 214, Section 5-1.1 1988. One method among other methods to abate the condition is to install a sprinkler system in the cooling tower area.
Recent events (2)
- — A (S)
- — Z (S)
10201 A
- Issued
- Feb 25, 1992
- Abate by
- Mar 30, 1992
General-duty citation text
Executive Order # 12196, Section # 1-201(a). The head of each agency shall furnish to employees places and conditions of employment that are free from recognized hazards that are causing or are likely to cause death or serious physical harm. The head of the agency did not furnish to employees places and conditions of employment that were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that, on October 4, 1991, the wooden cooling tower located on the roof of the J.F.K. Federal Building, Boston, MA., was not provided with a heat and smoke detection system as required by NFPA 214-Section 5-2.8.2 1988. One method among other methods to abate the condition is to install a heat and smoke detection system at the cooling tower.
Recent events (2)
- — A (S)
- — Z (S)
10201 A
- Issued
- Feb 25, 1992
- Abate by
- Mar 30, 1992
General-duty citation text
Executive Order # 12196, Section # 1-201(a). The head of each agency shall furnish to employees places and conditions of employment that are free from recognized hazards that are causing or are likely to cause death or serious physical harm. The head of the agency did not furnish to employees places and conditions of employment that were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that, on October 4, 1991, the roof of the J.F.K. Federal Building did not have adequate water pressure and volume of water to properly fight the fire which took place in the cooling tower, as required by NFPA-14, Section 5-3.1 1984. One method among other methods to abate the conditions is to install a fire pump within the building to provide and maintain the water pressure and volume as neccessary throughout the building.
Recent events (2)
- — A (S)
- — Z (S)
10201 A
- Issued
- Feb 25, 1992
- Abate by
- Mar 30, 1992
General-duty citation text
Executive Order # 12196, Section # 1-201(a). The head of each agency shall furnish to employees places and conditions of employment that are free from recognized hazards that are causing or are likely to cause death or serious physical harm. The head of the agency did not furnish to employees places and conditions of employment that were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that, the labels on the fire rated doors in stairwells 1 through 7 were painted over preventing the authority having jurisdiction from determining if the fire rating of the doors was adequate for their use, as required by NFPA 80 Section 1-5.1 1984. One method among other methods to abate the condition is to locate the neccessary documentation which would provide the actual rating of the fire rated doors in stairwells 1 through 7.
Recent events (2)
- — A (S)
- — Z (S)
10201 A
- Issued
- Feb 25, 1992
- Abate by
- Mar 30, 1992
General-duty citation text
Executive Order # 12196, Section # 1-201(a). The head of each agency shall furnish to employees places and conditions of employment that are free from recognized hazards that are causing or are likely to cause death or serious physical harm. The head of the agency did not furnish to employees places and conditions of employment that were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that, the door frames in stairwells 1 through 7 were not labeled preventing the authority having jurisdiction from determining if the frames had a fire rating adequate for their use as required by NFPA 80 Section 2-5.1 1984. One method among other methods to abate the condition is to locate the neccessary documentation which would indicate that the door frames are fire rated frames.
1910.36 B02
- Issued
- Feb 25, 1992
- Abate by
- Mar 30, 1992
1910.36 B04
- Issued
- Feb 25, 1992
- Abate by
- Mar 30, 1992
1910.36 B06
- Issued
- Feb 25, 1992
- Abate by
- Mar 30, 1992
1910.36 D02
- Issued
- Feb 25, 1992
- Abate by
- Mar 30, 1992
1910.37 D01
- Issued
- Feb 25, 1992
- Abate by
- Mar 30, 1992
1910.37 K01
- Issued
- Feb 25, 1992
- Abate by
- Mar 30, 1992
1910.37 K02
- Issued
- Feb 25, 1992
- Abate by
- Mar 30, 1992
1910.157 G01
- Issued
- Feb 25, 1992
- Abate by
- Mar 30, 1992
More inspections at U.S. Department of Health & Human Services
View U.S. Department of Health & Human Services's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 107535718.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.