OSHA Inspection: U.S. DEPARTMENT OF HEALTH & HUMAN SERVICES

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of U.S. DEPARTMENT OF HEALTH & HUMAN SERVICES in JFK FEDERAL BUILDING, GOVERNMENT CENTER, BOSTON, MA 02109 (NAICS 000000). OSHA activity number 107535718.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Department of Health & Human Services — free Get an email when a new federal OSHA severe-injury report for U.S. Department of Health & Human Services is published. One employer, no account, unsubscribe in one click.
Site address
JFK FEDERAL BUILDING, GOVERNMENT CENTER
City
BOSTON
State
MA
ZIP
02109
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
9431
Employees
400
Ownership type
D

13 citations on file for this inspection.

10201 A

Serious Gravity 05 3 instances 400 exposed
Issued
Feb 25, 1992
Abate by
Mar 30, 1992
Executive Order # 12196, Section # 1-201(a).  The head of each agency shall
furnish to employees places and conditions of employment that are free from
recognized hazards that are causing or are likely to cause death or serious
physical harm.  The head of the agency did not furnish to employees places
and conditions of employment that were free from recognized hazards that
were causing or likely to cause death or serious physical harm to employees ,
in that, on October 4, 1991, the wooden cooling tower located on the roof
of the J.F.K. Federal Building, Boston, MA., was not provided with a
sprinkler system as required by NFPA 214, Section 5-1.1 1988.
One method among other methods to abate the condition is to install a
sprinkler system in the cooling tower area.
Recent events (2)
  • — A (S)
  • — Z (S)

10201 A

Serious Gravity 05 192 instances 400 exposed
Issued
Feb 25, 1992
Abate by
Mar 30, 1992
Executive Order # 12196, Section # 1-201(a).  The head of each agency shall
furnish to employees places and conditions of employment that are free
from recognized hazards that are causing or are likely to cause death or
serious physical harm.
The head of the agency did not furnish to employees places
and conditions of employment that were free from recognized hazards that
were causing or likely to cause death or serious physical harm to
employees, in that, on October 4, 1991, the wooden cooling tower located
on the roof of the J.F.K. Federal Building, Boston, MA., was not provided
with a heat and smoke detection system as required by NFPA 214-Section
5-2.8.2 1988.
One method among other methods to abate the condition is to install a heat
and smoke detection system at the cooling tower.
Recent events (2)
  • — A (S)
  • — Z (S)

10201 A

Serious Gravity 05 12 instances 400 exposed
Issued
Feb 25, 1992
Abate by
Mar 30, 1992
Executive Order # 12196, Section # 1-201(a).  The head of each agency shall
furnish to employees places and conditions of employment that are free
from recognized hazards that are causing or are likely to cause death or
serious physical harm.
The head of the agency did not furnish to employees places
and conditions of employment that were free from recognized hazards that
were causing or likely to cause death or serious physical harm to
employees, in that, on October 4, 1991, the roof of the J.F.K. Federal
Building did not have adequate water pressure and volume of water to
properly fight the fire which took place in the cooling tower, as required
by NFPA-14, Section 5-3.1 1984.
One method among other methods to abate the conditions is to install a
fire pump within the building to provide and maintain the water pressure
and volume as neccessary throughout the building.
Recent events (2)
  • — A (S)
  • — Z (S)

10201 A

Serious Gravity 05 2 instances 400 exposed
Issued
Feb 25, 1992
Abate by
Mar 30, 1992
Executive Order # 12196, Section # 1-201(a).  The head of each agency shall
furnish to employees places and conditions of employment that are free
from recognized hazards that are causing or are likely to cause death or
serious physical harm.
The head of the agency did not furnish to employees places
and conditions of employment that were free from recognized hazards that
were causing or likely to cause death or serious physical harm to
employees, in that, the labels on the fire rated doors in stairwells 1
through 7 were painted over preventing the authority having jurisdiction
from determining if the fire rating of the doors was adequate for their
use, as required by NFPA 80 Section 1-5.1 1984.
One method among other methods to abate the condition is to locate the
neccessary documentation which would provide the actual rating of the fire
rated doors in stairwells 1 through 7.
Recent events (2)
  • — A (S)
  • — Z (S)

10201 A

Serious Gravity 05 48 instances 400 exposed
Issued
Feb 25, 1992
Abate by
Mar 30, 1992
Executive Order # 12196, Section # 1-201(a).  The head of each agency shall
furnish to employees places and conditions of employment that are free
from recognized hazards that are causing or are likely to cause death or
serious physical harm.
The head of the agency did not furnish to employees places
and conditions of employment that were free from recognized hazards that
were causing or likely to cause death or serious physical harm to
employees, in that, the door frames in stairwells 1 through 7 were not
labeled preventing the authority having jurisdiction from determining if
the frames had a fire rating adequate for their use as required by NFPA
80 Section 2-5.1 1984.
One method among other methods to abate the condition is to locate the
neccessary documentation which would indicate that the door frames are
fire rated frames.

1910.36 B02

Serious Gravity 05 107 instances 400 exposed
Issued
Feb 25, 1992
Abate by
Mar 30, 1992

1910.36 B04

Serious Gravity 05 5 instances 400 exposed
Issued
Feb 25, 1992
Abate by
Mar 30, 1992

1910.36 B06

Serious Gravity 05 12 instances 400 exposed
Issued
Feb 25, 1992
Abate by
Mar 30, 1992

1910.36 D02

Serious Gravity 05 4 instances 400 exposed
Issued
Feb 25, 1992
Abate by
Mar 30, 1992

1910.37 D01

Serious Gravity 05 48 instances 400 exposed
Issued
Feb 25, 1992
Abate by
Mar 30, 1992

1910.37 K01

Serious Gravity 05 5 instances 400 exposed
Issued
Feb 25, 1992
Abate by
Mar 30, 1992

1910.37 K02

Serious Gravity 05 4 instances 400 exposed
Issued
Feb 25, 1992
Abate by
Mar 30, 1992

1910.157 G01

Serious Gravity 05 400 instances 400 exposed
Issued
Feb 25, 1992
Abate by
Mar 30, 1992

View U.S. Department of Health & Human Services's full OSHA safety record →