Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DURO PLEATING CORP.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DURO PLEATING CORP. in 5711 KENNEDY BLVD., NORTH BERGEN, NJ 07047 (NAICS 000000). OSHA activity number 107658759.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Duro Pleating Corp. — free Get an email when a new federal OSHA severe-injury report for Duro Pleating Corp. is published. One employer, no account, unsubscribe in one click.
Establishment
DURO PLEATING CORP.
Site address
5711 KENNEDY BLVD.
City
NORTH BERGEN
State
NJ
ZIP
07047
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
2339
Employees
15
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 1 exposed
Issued
Mar 10, 1995
Abate by
Apr 24, 1995
Penalty
Initial $750 · Current $563 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees; in
that, employees were
exposed to the hazard of being struck by the ascending/descending elevator
car or falling into
the open hoistway.
Hoistway door was not provided with an interlock device.
Among methods one feasible and acceptable method to correct this hazard is
to:
1.  Equip the hoistway door with an interlock device.
2.  The interlock device shall hold the door in the locked position by
means of gravity
or by a restrained compression spring, or by both or by means of positive
linkage.
3.  The interlock shall lock the door in the closed position before the
elevator can be
operated.
Reference Publication(s)
A)  American National Standard Institute/American Society of Mechanical
Engineers
A17.3 - 1986 - Section 2.7.1(b).
Recent events (2)
  • — I (S) $562.50
  • — Z (S) $750.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 107658759.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.