FLUSHING, NY —
OSHA Inspection: EAST COAST STORAGE SYSTEMS
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of EAST COAST STORAGE SYSTEMS in 34-17 COLLEGE POINT BLVD., FLUSHING, NY 11354 (NAICS 000000). OSHA activity number 108684812.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EAST COAST STORAGE SYSTEMS
- Site address
- 34-17 COLLEGE POINT BLVD.
- City
- FLUSHING
- State
- NY
- ZIP
- 11354
- Mailing
- 207 FIRST STREET, LAKEWOOD, NJ 08701
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2542
- Employees
- 5
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- May 13, 1998
- Abate by
- May 18, 1998
- Penalty
- Initial $1,500 · Current $1,200 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by steel shelving unit and/or its contents: a)On 11/21/97 and 11/22/97 - Job site, 34-17 College Point Blvd. Employees worked and walked in the area in which a steel shelving unit, 104'L x 3'W x 14'H, was erected. The asphalt and concrete surface on which the shelving was erected was inadequate in strength to support the shelving. The concrete was not tested to determine the compressive strength of the area prior to installation. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE METHOD TO CORRECT THIS HAZARD IS TO: 1)Prior to installation, ascertain that the surface has adequate compressive strength to support the maximum intended load. Reference the American National Standard MH16.2-1984, Manual of Safety Practices-A Code of Safety Practices for the Use of Industrial and Commercial Steel Storage Racks, Section 1.4, Base Plates and Anchoring; Section 1.5g Moving Forces and Overturning; and Section 2.5, To Anchor or Not to Anchor. WRITTEN ABATEMENT VERIFICATION IS NOT REQUIRED.