TINLEY PARK, IL —
OSHA Inspection: P.T. FERRO CONSTRUCTION CO.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of P.T. FERRO CONSTRUCTION CO. in 6730 WEST 175TH STREET, TINLEY PARK, IL 60477 (NAICS 000000). OSHA activity number 108729153.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- P.T. FERRO CONSTRUCTION CO.
- Site address
- 6730 WEST 175TH STREET
- City
- TINLEY PARK
- State
- IL
- ZIP
- 60477
- Mailing
- P.O. BOX 156, 700 SOUTH ROWELL, JOLIET, IL 60477
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1611
- Employees
- 2
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jul 31, 1995
- Abate by
- Aug 3, 1995
- Penalty
- Initial $3,250 · Current $3,250
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and/or a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of oxygen deficiency and/or flammable and/or toxic atmospheres inside a communications manhole: a. On or about June 16, 1995, an employee was exposed to the hazards associated with improper confined space entry while working in communication manhole number nine. Prior to entry, a confined space entry procedure was not implemented, ie; an employee did not test the air, did not use continuous ventilation and did not have functioning atmospheric testing equipment. Among other methods, one feasible and acceptable abatement method to correct these hazards is to establish, implement and enforce an adequate confined space entry program such as that stipulated by ANSI Z117.1-1989, American National Standard Safety Requirements for Confined Spaces. Such a program shall include, as a minimum, the following elements: 1. Written procedures covering a permit system, ventilation, atmospheric testing, rescue procedures and employee training. 2. The completion and posting of a confined space entry permit which requires authorization and approval in writing that specifies the location and type of work to be done and certifies that all existing and potential hazards have been evaluated by a qualified person and that necessary measures have been taken to ensure the safety of each worker. 3. Blinding, blocking, bleeding, purging, lockout or any other steps necessary to reduce to and ensure zero mechanical and thermal state all mechanical, electrical, hydraulic, pneumatic, liquid and gas systems relating to the confined space that may create a hazard to employees during entry or while working in the confined space should any of these systems be put in motion or otherwise activated. 4. Mechanical ventilation of the confined space prior to entry and continued ventilation to provide a safe atmosphere, when determined necessary as described in (2) above. 5. Testing the atmosphere of the confined space prior to entry and on a regular basis for presence of sufficient oxygen (19.5) and absence of hazardous levels or toxic or combustible gases or vapors, when determined necessary as described in (2) above. 6. Emergency rescue procedures with requirement that trained personnel are available and are stationed outside the confined space with proper equipment to provide for the rescue of persons entering the space as determined necessary as described in (2) above. Such equipment must include safety harness and life lines with provisions for hoisting employees from the confined space. If entry is required for a rescue, the rescuing employee must be equipped with approved air supplied respiratory equipment and other appropriate personal protective equipment.7. Training of any and all employees required to entre the confined spaces and all employees required to standby for rescue. This training shall include procedures required prior to entry, during occupation of the confined space, procedures for safe rescue of employees in the confined space and the hazards associated with work in confined spaces.
Recent events (2)
- — F (S) $3250.00
- — Z (S) $3250.00
More inspections at P.T. Ferro Construction CO.
View P.T. Ferro Construction CO.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 108729153.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.