OSHA Inspection: STRIDE WELL SERVICE

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of STRIDE WELL SERVICE in 2 MI W, 3 1/2 MI S, 1/8 MI W, ENID, OK 73706 (NAICS 000000). OSHA activity number 108742321.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stride Well Service for free Get an email when a new federal OSHA severe-injury report for Stride Well Service is published. One employer, no account, unsubscribe in one click.
Establishment
STRIDE WELL SERVICE
Site address
2 MI W, 3 1/2 MI S, 1/8 MI W
City
ENID
State
OK
ZIP
73706
Mailing
P. O. BOX 10539, ENID, OK 73706
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1389
Employees
4
Ownership type
A
Industry flags
Construction safety.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 3 exposed
Issued
Dec 2, 1992
Abate by
Dec 7, 1992
Penalty
Initial $5,000 · Current $3,000 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment and a place of employment which
were free from recognized hazards that were causing or likely to cause
death or serious physical harm to employees in that employees were
exposed to the hazard of being struck by a falling pumping unit
horsehead:
Well site; employees engaged in the servicing of an oil/gas well worked
on the  well's head below the pumping unit horsehead, the horsehead
was not secured to the pumping unit walking beam, exposing the
employee(s) to the hazard of being struck by the falling horsehead.
Among other methods, one feasible and acceptable method to correct
this hazard is to ensure that the "throat" bolt be installed in the
position provided for it prior to employees being allowed in the area
beneath the horsehead.