EVANS CITY, PA —
OSHA Inspection: CALLERY CHEMICAL COMPANY
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of CALLERY CHEMICAL COMPANY in MARS-EVANS CITY ROAD, EVANS CITY, PA 16033 (NAICS 000000). OSHA activity number 108751694.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CALLERY CHEMICAL COMPANY
- Site address
- MARS-EVANS CITY ROAD
- City
- EVANS CITY
- State
- PA
- ZIP
- 16033
- Mailing
- P.O. BOX 429, PITTSBURGH, PA 15230
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2819
- Employees
- 125
- Ownership type
- A
Citations
30 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 8, 1996
- Abate by
- Aug 13, 1996
- Penalty
- Initial $235,000 · Current $235,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) Plantwide; Employees were potentially exposed to hazardous atmospheres (oxygen enriched/deficient, high levels of combustible gas, etc.) due to the fact that the company did not calibrate their environmental monitoring equipment before each use. Among others, one feasible and acceptable method of abatement is to have the environmental monitoring equipment properly calibrated before each use.
1910.146 D04 I
- Issued
- Aug 8, 1996
- Abate by
- Aug 13, 1996
1910.119 H02 I
- Issued
- Aug 8, 1996
- Abate by
- Aug 11, 1997
1910.119 H02 IV
- Issued
- Aug 8, 1996
- Abate by
- Aug 11, 1997
1910.119 H02 V
- Issued
- Aug 8, 1996
- Abate by
- Aug 11, 1997
1910.147 C04 I
- Issued
- Aug 8, 1996
- Abate by
- Aug 11, 1997
1910.147 C07 I
- Issued
- Aug 8, 1996
- Abate by
- Aug 11, 1997
1910.178 C02 IV
- Issued
- Aug 8, 1996
- Abate by
- Aug 13, 1996
5(a)(1)
- Issued
- Aug 8, 1996
- Abate by
- Oct 11, 1996
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees working in Building 86 were exposed to fire and/or explosion hazards. The following conditions contributed to the existence of this hazard: (a) There were inadequate methods to detect diborane leaks in the building, and; (b) The standard operating procedure - "Diborane Cylinder Receipt" did not clearly specify what amount of residue left in a cylinder after weighing would require the cylinder to be transferred to the Ice House. Feasible and accepted abatement methods, among others, include: 1. Installation of a diborane (Telos) sampling port in Building 86, (condition a); and 2. Updating the "Diborane Cylinder Receipt" standard operating procedure to clearly specify at what amount of residue left in a cylinder would require the cylinder to be transferred to the Ice House, (condition b).ndition
1910.36 B03
- Issued
- Aug 8, 1996
- Abate by
- Aug 13, 1996
1910.106 E06 II
- Issued
- Aug 8, 1996
- Abate by
- Aug 13, 1996
1910.120 Q02 VII
- Issued
- Aug 8, 1996
- Abate by
- Oct 11, 1996
1910.120 Q06
- Issued
- Aug 8, 1996
- Abate by
- Oct 11, 1996
1910.145 F05
- Issued
- Aug 8, 1996
- Abate by
- Oct 11, 1996
1910.1200 E01
- Issued
- Aug 8, 1996
- Abate by
- Oct 11, 1996
1910.146 D03 I
- Issued
- Aug 8, 1996
- Abate by
- Oct 11, 1996
1910.146 G04
- Issued
- Aug 8, 1996
- Abate by
- Oct 11, 1996
1910.147 C06 I
- Issued
- Aug 8, 1996
- Abate by
- Aug 11, 1997
1910.147 F02 I
- Issued
- Aug 8, 1996
- Abate by
- Aug 11, 1997
1910.304 F05 IVA
- Issued
- Aug 8, 1996
- Abate by
- Aug 13, 1996
1910.119 C02
- Issued
- Aug 8, 1996
- Abate by
- Feb 7, 1998
1910.119 D
- Issued
- Aug 8, 1996
- Abate by
- Feb 7, 1998
1910.119 D02 IA
- Issued
- Aug 8, 1996
- Abate by
- Feb 7, 1998
1910.119 E04
- Issued
- Aug 8, 1996
- Abate by
- Feb 7, 1998
1910.119 F01
- Issued
- Aug 8, 1996
- Abate by
- Feb 7, 1998
1910.119 J02
- Issued
- Aug 8, 1996
- Abate by
- Feb 7, 1998
1910.119 G01 I
- Issued
- Aug 8, 1996
- Abate by
- Feb 7, 1998
1910.119 I01
- Issued
- Aug 8, 1996
- Abate by
- Feb 7, 1998
1910.119 L01
- Issued
- Aug 8, 1996
- Abate by
- Feb 7, 1998
1910.119 F03
- Issued
- Aug 8, 1996
- Abate by
- Feb 7, 1998
More inspections at Callery Chemical Company
View Callery Chemical Company's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 108751694.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.