Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: ZAPCO ENERGY TACTICS CORP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ZAPCO ENERGY TACTICS CORP in 625 DUNBARTON ROAD, MANCHESTER LANDFILL, MANCHESTER, NH 01013 (NAICS 000000). OSHA activity number 108771031.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Zapco Energy Tactics Corp for free Get an email when a new federal OSHA severe-injury report for Zapco Energy Tactics Corp is published. One employer, no account, unsubscribe in one click.
Site address
625 DUNBARTON ROAD, MANCHESTER LANDFILL
City
MANCHESTER
State
NH
ZIP
01013
Mailing
124 SILLS ROAD, YAPHANK, NY 11890
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
4911
Employees
35
Ownership type
Private (A)

7 citations on file for this inspection.

1910.37 F02

Serious Gravity 10 2 instances 2 exposed
Issued
Jul 2, 1996
Abate by
Jul 8, 1996
Penalty
Initial $4,500 · Current $1,250 Reduced
Recent events (2)
  • · F (S) $1250.00
  • · Z (S) $4500.00

1910.269 D02 III

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 2, 1996
Abate by
Aug 6, 1996
Penalty
Initial $6,300 · Current $1,500 Reduced
Recent events (2)
  • · F (S) $1500.00
  • · Z (S) $6300.00

1910.269 D02 VI

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 2, 1996
Abate by
Aug 6, 1996
Penalty
Initial $6,300 · Current $1,500 Reduced
Recent events (2)
  • · F (S) $1500.00
  • · Z (S) $6300.00

1910.269 D03 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 2, 1996
Abate by
Aug 6, 1996
Penalty
Initial $6,300 · Current $1,500 Reduced
Recent events (2)
  • · F (S) $1500.00
  • · Z (S) $6300.00

1910.332 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 2, 1996
Abate by
Aug 6, 1996
Penalty
Initial $4,500 · Current $1,250 Reduced
Recent events (2)
  • · F (S) $1250.00
  • · Z (S) $4500.00

5(a)(1)

Unclassified Gravity 10 2 instances 2 exposed
Issued
Jul 2, 1996
Abate by
Jul 8, 1996
Penalty
Initial $63,000 · Current $26,500 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that two
employees were exposed to the hazard of fire/explosion:
a.Site - An automatic methane detection system had not been installed, on
or about
1/3/96.
ABATEMENT NOTE: Among other methods, one feasible and acceptable means
of abatement would be to install an automated methane detection system
whereby
if the levels of combustible gases reached 25of the LEL, all electrical
equipment in the enclosure would be shut down.
b.Site - The relief valve on the compressor gas receiver was not vented to
a safe
location, on or about 1/3/96.
ABATEMENT NOTE: Among other methods, one feasible and acceptable means
of abatement would be to comply with ASME Boiler and Pressure Vessel Code
Section VIII, paragraph UG-135.
c.Site - The relief valve on the compressor head was not vented to a safe
location,
on or about 1/3/96.
ABATEMENT NOTE: Among other methods, one feasible and acceptable means
of abatement would be to comply with ASME Boiler and Pressure Vessel Code
Section VIII, paragraph UG-135.
d.Site - The spacer vent on the Gardner-Denver compressor was not vented
to a
safe location, on or about 1/3/96.
ABATEMENT NOTE: Among other methods, one feasible and acceptable means
of abatement would be to pipe the valve to a safe area.
e.Site - A hand gate valve adjacent to the relief valve on the head was
not
vented
to a safe location, on or about 1/3/96.
ABATEMENT NOTE: Among other methods, one feasible and acceptable means
of abatement would be to install an automated methane detection system
whereby
if the levels of combustible gases reached 25of the LEL, all electrical
equipment in the enclosure would be shut down.
Recent events (2)
  • · F (U) $26500.00
  • · Z (W) $63000.00

1910.307 B

Willful Gravity 10 2 instances 2 exposed
Issued
Jul 2, 1996
Abate by
Jul 8, 1996
Penalty
Initial $63,000 · Current $26,500 Reduced
Recent events (2)
  • · F (W) $26500.00
  • · Z (W) $63000.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 108771031.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.