Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORTH ATLANTIC ENERGY SERVICE CORP.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NORTH ATLANTIC ENERGY SERVICE CORP. in ROUTE 1, LAFAYETTE ROAD, SEABROOK, NH 03874 (NAICS 000000). OSHA activity number 108780727.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch North Atlantic Energy Service Corp. — free Get an email when a new federal OSHA severe-injury report for North Atlantic Energy Service Corp. is published. One employer, no account, unsubscribe in one click.
Site address
ROUTE 1, LAFAYETTE ROAD
City
SEABROOK
State
NH
ZIP
03874
Mailing
BOX 300, SEABROOK, NH 03874
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
4911
Employees
931
Ownership type
A
Industry flags
Manufacturing safety.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 5 instances 15 exposed
Issued
Aug 4, 1994
Abate by
Sep 6, 1994
Penalty
Initial $4,500 · Current $2,700 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
%%
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed to hazards of the rapid release of energy due to pressure
differential between the inside
of the containment building and and the outside atmospheric pressure.
a.Containment Personnel Airlock - Employees working in and around the
Containment Building were not protected from the hazards associated with a
rapid
release of energy due to a lack of adequate procedures, lack of proper
equipment,
and a lack of adequate employee training.
ABATEMENT NOTE: Among other methods, the following is an acceptable
abatement method
to correct this hazard:  Develop procedures to do the job safely and
provide the equipment and
training necessary to implement the procedures.
Recent events (2)
  • — I (S) $2700.00
  • — Z (S) $4500.00

View North Atlantic Energy Service Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 108780727.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.