OSHA Inspection: AJ & JO PILAR, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AJ & JO PILAR, INC. in 145 CHAPEL STREET, NEWARK, NJ 07114 (NAICS 000000). OSHA activity number 108800681.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AJ & JO Pilar, INC. for free Get an email when a new federal OSHA severe-injury report for AJ & JO Pilar, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
AJ & JO PILAR, INC.
Site address
145 CHAPEL STREET
City
NEWARK
State
NJ
ZIP
07114
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
2865
Employees
7
Ownership type
Private (A)

1 citation on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jan 18, 1994
Abate by
Feb 22, 1994
Penalty
Initial $1,500 · Current $1,500
Section 5(a)(1) of the Occupational Safety & Health Act of 1970:
The employer did not furnish employment and a place of employment
which were free from recognized hazards that were causing or likely
to cause death or serious physical harm to employees in that
employees were exposed to:
a) 2 Lister Avenue
Employees were exposed to the hazard of being caught and/or crushed
between the elevator shaftway walls or sills.  Car gate was not
provided on the entrance side of elevator car.
Among other methods, one feasible and acceptable abatement method
to correct this hazard is to:
1) Provide car doors or gates on the entrance side equipped with
a car door or gate electric contact.
Reference Publication: ANSI/ASME A17.3-1986 Section 3.4.2. BOCA