Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: RUDY DRAGOJEVIC AND ASSOCIATES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RUDY DRAGOJEVIC AND ASSOCIATES, INC. in 200 CLEVELAND STREET, WARREN, OH 44483 (NAICS 000000). OSHA activity number 108847690.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rudy Dragojevic and Associates, INC. for free Get an email when a new federal OSHA severe-injury report for Rudy Dragojevic and Associates, INC. is published. One employer, no account, unsubscribe in one click.
Site address
200 CLEVELAND STREET
City
WARREN
State
OH
ZIP
44483
Mailing
5603 MAHONING AVENUE, N.W., WARREN, OH 44483
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
7933
Employees
5
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 5 exposed
Issued
Jul 8, 1993
Abate by
Jul 13, 1993
Penalty
Initial $750 · Current $750
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or about May 6, 1993, during the erection of the bowling alley,
employees were exposed to the hazards of serious injuries such as
lacerations, broken bones, or death from a roof collapse while installing
metal plate connected wood trusses approximately 87 foot long.  Inadequate
lateral bracing and inadequate top chord diagonal bracing were used for
the truss erection.
Among others, feasible and acceptable methods of abatement to include:
Establish proper spacing of both lateral bracing and top chord diagonal
bracing by use of a registered professional engineer for trusses over 60
foot in length as recommended by the Truss Plate Institute, and/or by
utilization of truss manufacturer's recommendations during the erection
of the trusses.

1903.2 A01

Other-than-serious Gravity 00 1 instance 5 exposed
Issued
Jul 8, 1993
Abate by
Jul 13, 1993

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 108847690.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.