WARREN, OH ·
OSHA Inspection: RUDY DRAGOJEVIC AND ASSOCIATES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of RUDY DRAGOJEVIC AND ASSOCIATES, INC. in 200 CLEVELAND STREET, WARREN, OH 44483 (NAICS 000000). OSHA activity number 108847690.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RUDY DRAGOJEVIC AND ASSOCIATES, INC.
- Site address
- 200 CLEVELAND STREET
- City
- WARREN
- State
- OH
- ZIP
- 44483
- Mailing
- 5603 MAHONING AVENUE, N.W., WARREN, OH 44483
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 7933
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 8, 1993
- Abate by
- Jul 13, 1993
- Penalty
- Initial $750 · Current $750
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: On or about May 6, 1993, during the erection of the bowling alley, employees were exposed to the hazards of serious injuries such as lacerations, broken bones, or death from a roof collapse while installing metal plate connected wood trusses approximately 87 foot long. Inadequate lateral bracing and inadequate top chord diagonal bracing were used for the truss erection. Among others, feasible and acceptable methods of abatement to include: Establish proper spacing of both lateral bracing and top chord diagonal bracing by use of a registered professional engineer for trusses over 60 foot in length as recommended by the Truss Plate Institute, and/or by utilization of truss manufacturer's recommendations during the erection of the trusses.
1903.2 A01
- Issued
- Jul 8, 1993
- Abate by
- Jul 13, 1993
More inspections in this industry (NAICS 000000)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 108847690.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.