ROCK HILL, NY —
OSHA Inspection: SULLIVAN FIRE PROTECTION CORP.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of SULLIVAN FIRE PROTECTION CORP. in MARGINAL ROAD, ROCK HILL, NY 12775 (NAICS 000000). OSHA activity number 108905878.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SULLIVAN FIRE PROTECTION CORP.
- Site address
- MARGINAL ROAD
- City
- ROCK HILL
- State
- NY
- ZIP
- 12775
- Mailing
- RAILROAD PLAZA, PO BOX V, SO. FALLSBURG, NY 12779
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1711
- Employees
- 2
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 23, 1992
- Abate by
- Oct 10, 1992
- Penalty
- Initial $600 · Current $300 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being pulled into and crushed by the rotating parts of a pipe threader: (a) 8/25/92 Basement area - A Rigid brand pipe threading machine Model 300 activated by an on-off switch that would not automatically shut the machine off if its operator was inadvertently caught up in its rotating parts. Among other methods, one feasible method to reduce this hazard is to establish & enforce adequate safe operating procedures such as those stipulated in ANSI B-208-1-1982 Portable Pipe Threading Machines. Elements essential to an acceptable safe operating procedure include at a minimum: 1. Installation of a momentary contact device (Deadman Foot Switch) to control power input to the machine. This device would automatically stop the machine and the rotating pipe if the operators' foot was removed from the foot switch for any reason. 2. Provide training and education to the machine operator concerning all the appropriate procedures for the safe operation and use of this tyoe of machinery.
Recent events (2)
- — F (S) $300.00
- — Z (S) $600.00
1926.59 E01
- Issued
- Sep 23, 1992
- Abate by
- Oct 11, 1992
- Penalty
- Initial $450 · Current $225 Reduced
Recent events (2)
- — F (S) $225.00
- — Z (S) $450.00
1926.59 H
- Issued
- Sep 23, 1992
- Abate by
- Oct 11, 1992
- Penalty
- Initial $450 · Current $225 Reduced
Recent events (2)
- — F (S) $225.00
- — Z (S) $450.00
1926.404 F07 IVC
- Issued
- Sep 23, 1992
- Abate by
- Sep 28, 1992
1926.416 E01
- Issued
- Sep 23, 1992
- Abate by
- Sep 28, 1992
More inspections at Sullivan Fire Protection Corp.
View Sullivan Fire Protection Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 108905878.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.