OSHA Inspection: ORR GROUP, INCORPORATED

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ORR GROUP, INCORPORATED in SCIENCE PARK & CIRCLEVILLE ROAD, STATE COLLEGE, PA 16801 (NAICS 000000). OSHA activity number 109030163.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ORR Group, Incorporated — free Get an email when a new federal OSHA severe-injury report for ORR Group, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
SCIENCE PARK & CIRCLEVILLE ROAD
City
STATE COLLEGE
State
PA
ZIP
16801
Mailing
428 7TH AVENUE, ALTOONA, PA 16602
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
1542
Employees
12
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 4 exposed
Issued
Jan 13, 1994
Abate by
Jan 31, 1994
Penalty
Initial $1,225 · Current $1,225
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:
The employer did not furnish employment and a place of employment
which were free from recognized hazards that were causing or likely
to cause death or serious physical harm to employees in that
employees were exposed to broken bones and concussions:
(a)  Free Methodist Church, Science Park Road and Circleville
Road, State College, Pennsylvania - The trusses that
collapsed were not provided with temporary bracing as
required by the Truss Plate Institute - there was
insufficient longitudinal and lateral bracing  ("X"
and"W" bracing) which contributed to the collapse of the
trusses, on or about November 8, 1993.
"AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD
TO CORRECT THIS HAZARD IS FOR THE CONTRACTOR TO FOLLOW THE
RECOMMENDED PRACTICE OF INSTALLING THE TEMPORARY BRACING AS
REQUIRED BY THE TRUSS PLATE INSTITUTE..."