PARIS, TX —
OSHA Inspection: PHILIPS LIGHTING COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PHILIPS LIGHTING COMPANY in 3010 CLARKKSVILLE STREET, PARIS, TX 75460 (NAICS 000000). OSHA activity number 109103937.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PHILIPS LIGHTING COMPANY
- Site address
- 3010 CLARKKSVILLE STREET
- City
- PARIS
- State
- TX
- ZIP
- 75460
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3641
- Employees
- 153
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
15 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 24, 1994
- Abate by
- Nov 3, 1994
- Penalty
- Initial $5,000 · Current $3,250 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: Explosion and fire hazards created by natural gas lines located at ceiling level that were not identified or labelled as to the contents. The gas lines ran through manufacturing areas in the plant. Feasible abatement methods to correct this hazard may include, but are not limited to: a) Positive identification of the contents of the piping system by lettered legend giving the name of the contents in full and pressure; b) Arrows shall be used to indicate direction of flow; c) Legends shall be applied close to valves and adjacent to changes in direction, branches and where pipes pass through walls or floors and at frequent intervals on straight pipe runs (sufficient to identify clearly); d) Identification may be accomplished by stenciling, the use of tape or markers; e) Where pipe lines are located above the normal line of vision the lettering shall be placed below the horizontal centerline of the pipe; f) Maximum contrast shall be provided between color field and legend for readability. For flammable or explosive materials the colors shall be yellow and black; g) Use of letters of standard style, in sizes 1/2" and larger is recommended as required by ANSI A13.1-1975, Scheme for the Identification of Piping Systems, Sections 3.1, 3.2, 3.3 and 3.4.
Recent events (2)
- — I (S) $3250.00
- — Z (S) $5000.00
1910.147 D03
- Issued
- Oct 24, 1994
- Abate by
- Oct 28, 1994
- Penalty
- Initial $5,000 · Current $3,250 Reduced
Recent events (2)
- — I (S) $3250.00
- — Z (S) $5000.00
1910.212 A01
- Issued
- Oct 24, 1994
- Abate by
- Nov 1, 1994
- Penalty
- Initial $3,500 · Current $2,275 Reduced
Recent events (2)
- — I (S) $2275.00
- — Z (S) $3500.00
1910.212 A03 II
- Issued
- Oct 24, 1994
- Abate by
- Nov 3, 1994
- Penalty
- Initial $5,000 · Current $3,250 Reduced
Recent events (2)
- — I (S) $3250.00
- — Z (S) $5000.00
1910.215 A04
- Issued
- Oct 24, 1994
- Abate by
- Oct 28, 1994
- Penalty
- Initial $2,000 · Current $1,300 Reduced
Recent events (2)
- — I (S) $1300.00
- — Z (S) $2000.00
1910.215 B09
- Issued
- Oct 24, 1994
- Abate by
- Oct 28, 1994
- Penalty
- Initial $2,000 · Current $1,300 Reduced
Recent events (2)
- — I (S) $1300.00
- — Z (S) $2000.00
1910.242 B
- Issued
- Oct 24, 1994
- Abate by
- Nov 3, 1994
- Penalty
- Initial $2,000 · Current $1,300 Reduced
Recent events (2)
- — I (S) $1300.00
- — Z (S) $2000.00
1910.253 B04 III
- Issued
- Oct 24, 1994
- Abate by
- Oct 28, 1994
- Penalty
- Initial $1,500 · Current $975 Reduced
Recent events (2)
- — I (S) $975.00
- — Z (S) $1500.00
1910.305 G01 III
- Issued
- Oct 24, 1994
- Abate by
- Oct 28, 1994
- Penalty
- Initial $2,500 · Current $1,625 Reduced
Recent events (2)
- — I (S) $1625.00
- — Z (S) $2500.00
1910.37 Q06
- Issued
- Oct 24, 1994
- Abate by
- Nov 1, 1994
1910.106 D02 I
- Issued
- Oct 24, 1994
- Abate by
- Nov 3, 1994
1910.157 C01
- Issued
- Oct 24, 1994
- Abate by
- Oct 28, 1994
1910.1200 F05 I
- Issued
- Oct 24, 1994
- Abate by
- Oct 28, 1994
1910.1200 F05 II
- Issued
- Oct 24, 1994
- Abate by
- Oct 28, 1994
1910.303 F
- Issued
- Oct 24, 1994
- Abate by
- Oct 28, 1994
More inspections at Philips Lighting Company
View Philips Lighting Company's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 109103937.