OSHA Inspection: MASS BAY ELECTRICAL CORPORATION

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of MASS BAY ELECTRICAL CORPORATION in CP402, DEER ISLAND, WINTHROP, MA 02152 (NAICS 000000). OSHA activity number 109128561.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mass BAY Electrical Corporation — free Get an email when a new federal OSHA severe-injury report for Mass BAY Electrical Corporation is published. One employer, no account, unsubscribe in one click.
Site address
CP402, DEER ISLAND
City
WINTHROP
State
MA
ZIP
02152
Mailing
125 ORLEANS STREET, EAST BOSTON, MA 02128
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1731
Employees
5
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 7, 1994
Abate by
May 13, 1994
Penalty
Initial $2,000 · Current $1,000 Reduced
Section 5(a)(1) of the Occupational Safety & Health Act of 1970:  The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees,
in that, employees were
exposed to the hazard of delayed rescue and possible injury during entry
and exit from
manhole:
CP402/427; Manhole3A, Deer Island:
On November 8, 1993, and December 2, 1993, employees were exposed to the
hazard
of delayed rescue and possible injury during entry and exit from
Manhole3A, on West
Perimeter Road.
A feasible and useful method to correct this hazard, among other methods,
is to institute an
effective confined space entry program meeting the requirements of OSHA
29 CFR 1910.146
and/or ANSI Z117.11989.
The program should include:
1)Effective training of the authorized entrants, attendants and all
affected employees.
2)Develop, implement, and correctly complete all portions of entry
permit.  The permit
should specify the nature of the work to be conducted and all necessary
equipment,
including rescue equipment.
3)Use of effective retrieval device such as a winch and tripod with a
fall arrest system
where self rescue may fail and vertical retrieval is necessary.
4)Continuous air monitoring where there is a potential for entry of toxic
or hazardous air
contaminants.
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $2000.00

1926.21 B06 I

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 7, 1994
Abate by
May 13, 1994
Penalty
Initial $2,000 · Current $1,000 Reduced
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $2000.00

View Mass BAY Electrical Corporation's full OSHA safety record →