WINTHROP, MA —
OSHA Inspection: MASS BAY ELECTRICAL CORPORATION
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of MASS BAY ELECTRICAL CORPORATION in CP402, DEER ISLAND, WINTHROP, MA 02152 (NAICS 000000). OSHA activity number 109128561.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MASS BAY ELECTRICAL CORPORATION
- Site address
- CP402, DEER ISLAND
- City
- WINTHROP
- State
- MA
- ZIP
- 02152
- Mailing
- 125 ORLEANS STREET, EAST BOSTON, MA 02128
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1731
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 7, 1994
- Abate by
- May 13, 1994
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety & Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that, employees were exposed to the hazard of delayed rescue and possible injury during entry and exit from manhole: CP402/427; Manhole3A, Deer Island: On November 8, 1993, and December 2, 1993, employees were exposed to the hazard of delayed rescue and possible injury during entry and exit from Manhole3A, on West Perimeter Road. A feasible and useful method to correct this hazard, among other methods, is to institute an effective confined space entry program meeting the requirements of OSHA 29 CFR 1910.146 and/or ANSI Z117.11989. The program should include: 1)Effective training of the authorized entrants, attendants and all affected employees. 2)Develop, implement, and correctly complete all portions of entry permit. The permit should specify the nature of the work to be conducted and all necessary equipment, including rescue equipment. 3)Use of effective retrieval device such as a winch and tripod with a fall arrest system where self rescue may fail and vertical retrieval is necessary. 4)Continuous air monitoring where there is a potential for entry of toxic or hazardous air contaminants.
Recent events (2)
- — I (S) $1000.00
- — Z (S) $2000.00
1926.21 B06 I
- Issued
- Apr 7, 1994
- Abate by
- May 13, 1994
- Penalty
- Initial $2,000 · Current $1,000 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $2000.00
More inspections at Mass BAY Electrical Corporation
View Mass BAY Electrical Corporation's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 109128561.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.