SAVANNAH, GA —
OSHA Inspection: INTERNATIONAL CHIMNEY CORPORATION
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of INTERNATIONAL CHIMNEY CORPORATION in 42 EAST BROAD STREET, SAVANNAH, GA 31401 (NAICS 000000). OSHA activity number 109146985.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTERNATIONAL CHIMNEY CORPORATION
- Site address
- 42 EAST BROAD STREET
- City
- SAVANNAH
- State
- GA
- ZIP
- 31401
- Mailing
- 55 SOUTH LONG STREET, WILLIAMSVILLE, NY 14221
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1799
- Employees
- 6
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Feb 19, 2002
- Abate by
- Feb 22, 2002
- Penalty
- Initial $4,900 · Current $1,500 Reduced
General-duty citation text
P.L. 91-596 Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees involved in relocating a building were exposed to the hazards of being struck by debris or crushed by the collapse of the building: A). Building No. 1, located on East Bay Street, Savannah, Georgia. The cribbing/moving system used to support the weight of the building during the relocation phase was improperly designed. The silty sand soil supporting the cribbing/moving system was subjected to loads higher than its ultimate capacity and many time higher than its safe bearing capacity, on or about 08/30/2001. B). Building No. 1, located on east bay Street, Savannah, Georgia. The structural design of the connection plates between the "move-steel" beams was deficient. The connection plates were undersized, on or about 08/30/2001. Among other methods, one feasible and acceptable method to correct this hazard is to: 1. Analyze and evaluate the nature and the characteristics (e.g., safe load bearing capacity) of the soil located under and in the vicinity of the building to be relocated. 2. Design and properly size the cribbing used to support the building weight during the relocation phase to ensure that the safe bearing capacity of the soil is not exceeded. 3. Properly design and construct the connection plates between the "move-steel" beams.
Recent events (2)
- — F (S) $1500.00
- — Z (S) $4900.00
More inspections at International Chimney Corporation
View International Chimney Corporation's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 109146985.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.