FRANKLIN, MA —
OSHA Inspection: PENT HOUSE SALES CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PENT HOUSE SALES CORPORATION in 860 WEST CENTRAL STREET, FRANKLIN, MA 02038 (NAICS 000000). OSHA activity number 109171637.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PENT HOUSE SALES CORPORATION
- Site address
- 860 WEST CENTRAL STREET
- City
- FRANKLIN
- State
- MA
- ZIP
- 02038
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3131
- Employees
- 20
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 13, 1995
- Abate by
- Jan 2, 1996
- Penalty
- Initial $225 · Current $113 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety & Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death of serious physical harm to employees, in that, employees were exposed to the hazards of falling down the hoistway shaft when the elevator car was not in the landing zone, being struck by the elevator car when the car was entering or leaving the landing zone or having part of their body caught between the moving elevator and the hoistway. A feasible and useful method to correct this hazard, among other methods, is to provide elevator hoistway or landing doors or gates that are electrically interlocked to prevent the elevator car from moving when the landing doors or gates are in the open position and so latched that the landing doors or gates cannot be opened from the landing side unless the elevator car is within the landing zone: Establishment: The elevator was not equipped with landing doors that were electrically and mechanically interlocked and at least five feet six inches in height.
Recent events (3)
- — P (S) $112.50
- — I (S) $112.50
- — Z (S) $225.00
1910.219 C02 I
- Issued
- Oct 13, 1995
- Abate by
- Dec 1, 1995
- Penalty
- Initial $225 · Current $113 Reduced
Recent events (2)
- — I (S) $112.50
- — Z (S) $225.00
1910.219 C04 I
- Issued
- Oct 13, 1995
- Abate by
- Dec 1, 1995
1910.219 D01
- Issued
- Oct 13, 1995
- Abate by
- Jan 2, 1996
- Penalty
- Initial $225 · Current $113 Reduced
Recent events (3)
- — P (S) $112.50
- — I (S) $112.50
- — Z (S) $225.00
1910.219 F01
- Issued
- Oct 13, 1995
- Abate by
- Jan 2, 1996
- Penalty
- Initial $225 · Current $113 Reduced
Recent events (3)
- — P (S) $112.50
- — I (S) $112.50
- — Z (S) $225.00
1910.147 C01
- Issued
- Oct 13, 1995
- Abate by
- Dec 1, 1995
1910.215 A02
- Issued
- Oct 13, 1995
- Abate by
- Dec 1, 1995
1910.215 B09
- Issued
- Oct 13, 1995
- Abate by
- Dec 1, 1995
1910.304 F05 V
- Issued
- Oct 13, 1995
- Abate by
- Dec 1, 1995
1910.305 G01 III
- Issued
- Oct 13, 1995
- Abate by
- Dec 1, 1995
More inspections in this industry (NAICS 000000)