BOSTON, MA —
OSHA Inspection: ANALYTIC POWER CORPORATION
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of ANALYTIC POWER CORPORATION in 268 SUMMER STREET, BOSTON, MA 02210 (NAICS 000000). OSHA activity number 109173229.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANALYTIC POWER CORPORATION
- Site address
- 268 SUMMER STREET
- City
- BOSTON
- State
- MA
- ZIP
- 02210
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 8711
- Employees
- 16
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.20 E03 I
- Issued
- Feb 23, 1996
- Abate by
- Feb 28, 1996
- Penalty
- Initial $600 · Current $300 Reduced
Recent events (2)
- — F (S) $300.00
- — Z (S) $600.00
1910.101 B
- Issued
- Feb 23, 1996
- Abate by
- Feb 29, 1996
- Penalty
- Initial $1,000 · Current $1,000
Recent events (2)
- — F (S) $1000.00
- — Z (S) $1000.00
1910.151 C
- Issued
- Feb 23, 1996
- Abate by
- Feb 29, 1996
- Penalty
- Initial $2,000 · Current $1,700 Reduced
Recent events (2)
- — F (S) $1700.00
- — Z (S) $2000.00
1910.157 C01
- Issued
- Feb 23, 1996
- Abate by
- Feb 29, 1996
- Penalty
- Initial $1,400 · Current $1,400
Recent events (2)
- — F (S) $1400.00
- — Z (S) $1400.00
1910.157 D01
- Issued
- Feb 23, 1996
- Abate by
- Mar 20, 1996
Recent events (2)
- — F (S)
- — Z (S)
1910.157 E03
- Issued
- Feb 23, 1996
- Abate by
- Feb 29, 1996
Recent events (2)
- — F (S)
- — Z (S)
1910.157 G01
- Issued
- Feb 23, 1996
- Abate by
- Feb 29, 1996
Recent events (2)
- — F (S)
- — Z (S)
1910.1450 E01
- Issued
- Feb 23, 1996
- Abate by
- Mar 20, 1996
- Penalty
- Initial $1,400 · Current $1,400
Recent events (2)
- — F (S) $1400.00
- — Z (S) $1400.00
1910.1450 F01
- Issued
- Feb 23, 1996
- Abate by
- Mar 20, 1996
- Penalty
- Initial $2,000 · Current $1,700 Reduced
Recent events (2)
- — F (S) $1700.00
- — Z (S) $2000.00
5(a)(1)
- Issued
- Feb 23, 1996
- Abate by
- Oct 31, 1996
- Penalty
- Initial $28,000 · Current $6,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: physical injury from an exploding reactor bottle, which occurred during a Hydrogen Gas generation experiment: Analytic Power Incorporated, Research Lab: On August 29, 1995, an employee was monitoring the reaction of powdered Sodium Borohydride and water to produce Hydrogen Gas. This employee and another nearby employee suffered severe burn injuries when the Aluminum reactor bottle exploded. The explosion occurred when the reactor bottle underwent hoop stress failure as a result of an exothermic Hydrogen Gas generation reaction. Among other methods, several acceptable abatement methods to correct this hazard include, but are not limited to: 1)Develop engineering controls in accordance with National Safety Council recommendations for safe usage of metal hydrides, in accordance with DIERS technology, and/or other industry recommended practices, to ensure that experimental equipment is designed, maintained, inspected, and operated in a safe manner: -Installation of physical barricades around the reactor bottles. -Utilization of stainless steel for the processing equipment. -Installation of adequate ventilation to remove hydrogen. -Exhaust lines should be of large diameter and should lead away from personnel, equipment, and moisture. -Utilization of an explosion-suppression system. -Elimination of ignition sources in the vicinity of the hydrogen generation equipment, including installation of explosion-proof electrical equipment, and grounding of all equipment and associated piping to avoid generation of static electricity. -Implementation of standard operating procedures to prevent formation of flammable mixtures. 2)Design an operating strategy, based on the results of a completed hazard analysis, that will help to prevent or minimize the consequences of releases of toxic, reactive, flammable, or explosive chemicals: -Identification of potential problems with the system, through initial acquisition and analysis of chemical, physical, and other relevant data. -Measurement and control of critical parameters (temperature, pressure, feed rate, coolant flow, catalyst level). -Operation at conditions (temperature, pressure, concentration) that provide a safe margin from runaway conditions. -Installation of redundant instrumentation to increase reliability of measurement and control of critical parameters.-Use of alarms to warn operators that a critical parameter has changed from its normal condition. -Provision of training to enable operators to safely react to upset conditions. This includes development and implementation of SOPS (standard operating procedures) that provide clear instructions for safely conducting activities. -Activation of an automatic emergency shutdown when a critical parameter has deviated from normal by a pre-determined amount. -Design and installation of an emergency relief system to include safe disposal of the discharged material, and to prevent over-pressurization of the equipment. -Prevention of chemical/equipment contamination by proper design and operating procedures.
Recent events (2)
- — F (U) $6000.00
- — Z (W) $28000.00
More inspections at Analytic Power Corporation
View Analytic Power Corporation's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 109173229.