Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PALL AEROPOWER CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PALL AEROPOWER CORPORATION in 4245 EVANS AVENUE, FT. MYERS, FL 33901 (NAICS 000000). OSHA activity number 109201376.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pall Aeropower Corporation — free Get an email when a new federal OSHA severe-injury report for Pall Aeropower Corporation is published. One employer, no account, unsubscribe in one click.
Site address
4245 EVANS AVENUE
City
FT. MYERS
State
FL
ZIP
33901
Mailing
5775 RIO VISTA DRIVE, CLEARWATER, FL 33760
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3599
Employees
180
Ownership type
A
Industry flags
Manufacturing safety.

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 1 instance 10 exposed
Issued
Apr 26, 1995
Abate by
May 29, 1995
Penalty
Initial $1,300 · Current $1,300
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:
The employer did not furnish employment and a place of employment which
were free from
recognized hazards that were causing or likely to cause death or serious
physical harm to
employees in that employees were exposed to striking/crushing hazards:
a). Assembly Area and throughout the entire facility to include jib and
other cranes - The
Underhung monorail Coffing 1/2 ton crane which had been moved to this area
did not have its
structure load tested; was missing mechanical stops for the trolley on the
rail; no frequent (daily
visual) inspections by the operators of the crane's chains, hooks, limit
switches, trolley, swivels,
and safety devices for physical defects; no records of the inspection of
critical items; and no
preventative maintenance records as required by the American National
Standards Institute
B30.16 - 1973, Monorail Systems and Underhung Cranes an B30.11 - 1973,
Overhead Hoists,
on or about 04/11/95.
Among other methods, one feasible and acceptable method to correct this
hazard is to train crane
and hoist operators on when and how to conduct frequent inspections,
immediately report unsafe
conditions of the crane to management for action. Maintenance personnel
also need to receive
training on the requirements of inspection records, the need for load
testing before use after
installation, and the installation of rail stops for the hoist trolleys.

1910.305 G01 III

Serious Gravity 02 1 instance 1 exposed
Issued
Apr 26, 1995
Abate by
May 2, 1995
Penalty
Initial $1,300 · Current $1,300

1910.37 Q02

Other-than-serious Gravity 01 1 instance 5 exposed
Issued
Apr 26, 1995
Abate by
May 10, 1995

View Pall Aeropower Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 109201376.