FT. MYERS, FL —
OSHA Inspection: PALL AEROPOWER CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PALL AEROPOWER CORPORATION in 4245 EVANS AVENUE, FT. MYERS, FL 33901 (NAICS 000000). OSHA activity number 109201376.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PALL AEROPOWER CORPORATION
- Site address
- 4245 EVANS AVENUE
- City
- FT. MYERS
- State
- FL
- ZIP
- 33901
- Mailing
- 5775 RIO VISTA DRIVE, CLEARWATER, FL 33760
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3599
- Employees
- 180
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 26, 1995
- Abate by
- May 29, 1995
- Penalty
- Initial $1,300 · Current $1,300
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to striking/crushing hazards: a). Assembly Area and throughout the entire facility to include jib and other cranes - The Underhung monorail Coffing 1/2 ton crane which had been moved to this area did not have its structure load tested; was missing mechanical stops for the trolley on the rail; no frequent (daily visual) inspections by the operators of the crane's chains, hooks, limit switches, trolley, swivels, and safety devices for physical defects; no records of the inspection of critical items; and no preventative maintenance records as required by the American National Standards Institute B30.16 - 1973, Monorail Systems and Underhung Cranes an B30.11 - 1973, Overhead Hoists, on or about 04/11/95. Among other methods, one feasible and acceptable method to correct this hazard is to train crane and hoist operators on when and how to conduct frequent inspections, immediately report unsafe conditions of the crane to management for action. Maintenance personnel also need to receive training on the requirements of inspection records, the need for load testing before use after installation, and the installation of rail stops for the hoist trolleys.
1910.305 G01 III
- Issued
- Apr 26, 1995
- Abate by
- May 2, 1995
- Penalty
- Initial $1,300 · Current $1,300
1910.37 Q02
- Issued
- Apr 26, 1995
- Abate by
- May 10, 1995
More inspections at Pall Aeropower Corporation
View Pall Aeropower Corporation's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 109201376.