ORLANDO, FL —
OSHA Inspection: TCR CONSTRUCTION, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of TCR CONSTRUCTION, INC. in 6168 W. RALEIGH STREET, ORLANDO, FL 32835 (NAICS 000000). OSHA activity number 109315796.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TCR CONSTRUCTION, INC.
- Site address
- 6168 W. RALEIGH STREET
- City
- ORLANDO
- State
- FL
- ZIP
- 32835
- Mailing
- 541 S. ORLANDO AVE. #210, MAITLAND, FL 32751
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1522
- Employees
- 3
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
2 citations on file for this inspection.
1926.501 B04 I
- Issued
- Jan 22, 1998
- Abate by
- Jan 27, 1998
- Penalty
- Initial $525 · Current $525
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to the hazard of being struck by or caught under a collapsing roof truss system due to lack of bracing of the truss system: (a) On Building 28 of the Vinings Club at Metrowest complex, the metal plate connected wood roof truss system had not been adequately braced relative to the amount of bracing needed, the size of the bracing material used, and the locations of the braces to prevent collapse, and concrete roof tiles were placed on the unbraced roof system, increasing the likelihood of collapse, on or about August 18, 1997. One feasible and acceptable method of abatement, among other methods, to correct this hazard is to brace the trusses in accordance with the recommendations in HIB-91, "Handling, Installing & Bracing Metal Plate Connected Wood Trusses" from the Truss Plate Institute, or the bracing recommendations of a registered professional engineer, and to prohibit the placing of material on the roof until adequate bracing has been installed.
1926.1052 C01
- Issued
- Jan 22, 1998
- Abate by
- Jan 27, 1998
- Penalty
- Initial $225 · Current $225
More inspections at TCR Construction, INC.