WEST HAZLETON, PA —
OSHA Inspection: GENERAL FOAM - DIVISION OF PMC INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of GENERAL FOAM - DIVISION OF PMC INC. in 25 JAYCEE DRIVE, VALMONT INDUSTRIAL PARK, WEST HAZLETON, PA 18201 (NAICS 000000). OSHA activity number 109357079.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GENERAL FOAM - DIVISION OF PMC INC.
- Site address
- 25 JAYCEE DRIVE, VALMONT INDUSTRIAL PARK
- City
- WEST HAZLETON
- State
- PA
- ZIP
- 18201
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3069
- Employees
- 300
- Ownership type
- A
Citations
17 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 1, 1992
- Abate by
- Jul 4, 1992
- Penalty
- Initial $2,500 · Current $1,250 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential vessel over-pressurization hazards from the failure of a low pressure storage vessel: a) Plant 4 Tank Room; the steel storage tank used to contain Cymel 481 Resin was exposed to approximately six psig pressure and was not certified for use as a low pressure storage tank as defined by Subparagraph 5.23, Recommended Rules for Design and Construction of Large, Welded, Low-Pressure Storage Tanks, of the American Petroleum Institute Standard 620-1966, January 17, 1992. FEASIBLE AND USEFUL METHODS OF ABATEMENT INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: 1) Develop an inspection and maintenance program for low pressure storage tanks to insure compliance; 2) Replace the existing vessel with a certified pressure vessel.
Recent events (2)
- — I (S) $1250.00
- — Z (S) $2500.00
1910.23 C01
- Issued
- Jun 1, 1992
- Abate by
- Jul 19, 1992
- Penalty
- Initial $2,000 · Current $1,000 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $2000.00
1910.25 D02 XII
- Issued
- Jun 1, 1992
- Abate by
- Jun 4, 1992
- Penalty
- Initial $2,000
Recent events (2)
- — I (O)
- — Z (S) $2000.00
1910.106 E07 IC
- Issued
- Jun 1, 1992
- Abate by
- Jun 19, 1992
- Penalty
- Initial $2,500 · Current $750 Reduced
Recent events (2)
- — I (S) $750.00
- — Z (S) $2500.00
1910.120 Q06 IIIA
- Issued
- Jun 1, 1992
- Abate by
- Sep 4, 1992
- Penalty
- Initial $2,500 · Current $1,250 Reduced
24701290
Recent events (2)
- — I (S) $1250.00
- — Z (S) $2500.00
1910.120 Q06 IIIC
- Issued
- Jun 1, 1992
- Abate by
- Sep 4, 1992
24901290
Recent events (2)
- — I (S)
- — Z (S)
1910.120 Q06 IIID
- Issued
- Jun 1, 1992
- Abate by
- Sep 4, 1992
24701290
Recent events (2)
- — I (S)
- — Z (S)
1910.120 Q06 IIIE
- Issued
- Jun 1, 1992
- Abate by
- Sep 4, 1992
24701290
Recent events (2)
- — I (S)
- — Z (S)
1910.120 Q06 IIIF
- Issued
- Jun 1, 1992
- Abate by
- Sep 4, 1992
24701290
Recent events (2)
- — I (S)
- — Z (S)
1910.120 Q06 IIIG
- Issued
- Jun 1, 1992
- Abate by
- Sep 4, 1992
24701290
Recent events (2)
- — I (S)
- — Z (S)
1910.120 Q06 IIIH
- Issued
- Jun 1, 1992
- Abate by
- Sep 4, 1992
24701290
Recent events (2)
- — I (S)
- — Z (S)
1910.120 Q08 I
- Issued
- Jun 1, 1992
- Abate by
- Sep 4, 1992
12902470
Recent events (2)
- — I (S)
- — Z (S)
1910.212 A01
- Issued
- Jun 1, 1992
- Abate by
- Aug 1, 1992
- Penalty
- Initial $2,000 · Current $1,000 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $2000.00
1910.22 A02
- Issued
- Jun 1, 1992
- Abate by
- Jun 19, 1992
1910.132 A
- Issued
- Jun 1, 1992
- Abate by
- Jul 19, 1992
Recent events (2)
- — I (O)
- — Z (O)
1910.1048 J03
- Issued
- Jun 1, 1992
- Abate by
- Jul 19, 1992
1290
Recent events (2)
- — I (O)
- — Z (O)
1926.58 L02
- Issued
- Jun 1, 1992
- Abate by
- Jun 19, 1992
9020
More inspections at General Foam - Division of PMC INC.
View General Foam - Division of PMC INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 109357079.