CARBONDALE, PA —
OSHA Inspection: GENTEX CORP
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of GENTEX CORP in BELMONT STREET, CARBONDALE, PA 18407 (NAICS 000000). OSHA activity number 109363317.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GENTEX CORP
- Site address
- BELMONT STREET
- City
- CARBONDALE
- State
- PA
- ZIP
- 18407
- Mailing
- P.O. BOX 315, CARBONDALE, PA 18470
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3089
- Employees
- 300
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 6, 1996
- Abate by
- Oct 9, 1996
- Penalty
- Initial $2,275 · Current $2,275
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: %% (a) The two jacketed reactors used for the production of dye were not equipped with high temperature alarms to alert employees of an exothermic condition and the possible release of toxic air contaminants. (b) The two jacketed reactors used for the production of dye were not equipped with an automatic cooling system to prevent overheating of the reaction and the possible release of toxic air contaminants. ABATEMENT NOTE: General methods of abatement include, but are not limited to, the following: 1. Install, calibrate, and maintain instrumentation to detect temperatures outside the prescribed range for this reaction and to initiate a cool down of the reactor.
1910.106 E06 II
- Issued
- Sep 6, 1996
- Abate by
- Oct 9, 1996
- Penalty
- Initial $975 · Current $975
1910.151 C
- Issued
- Sep 6, 1996
- Abate by
- Oct 9, 1996
- Penalty
- Initial $975 · Current $975
1910.120 Q08 I
- Issued
- Sep 6, 1996
- Abate by
- Oct 9, 1996
More inspections at Gentex Corp
View Gentex Corp's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 109363317.