DUTCH HARBOR, AK ·
OSHA Inspection: PANKOF FISHERIES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PANKOF FISHERIES in F/V RESPONSE, DUTCH HARBOR, AK 99692 (NAICS 000000). OSHA activity number 109432104.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PANKOF FISHERIES
- Site address
- F/V RESPONSE
- City
- DUTCH HARBOR
- State
- AK
- ZIP
- 99692
- Mailing
- 7220 GALLAGHER COVE RD. N.W., OLYMPIA, WA 98502
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2092
- Employees
- 15
- Ownership type
- Private (A)
- Industry flags
- Maritime safety.
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- May 19, 1993
- Abate by
- Jun 21, 1993
- Penalty
- Initial $3,000 · Current $714 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the inadvertent restart of equipment during maintenance procedures: (a) F/V Response: In the processing area, mechanical, electrical and engine rooms, there were no written procedures, rules or training developed or implemented on energy controls for employees' protection and training against hazards such as bruises, contusion, fractures and death when they work on repairing processing equipment, mechanical, electrical and engine room equipment in accordance with 29 CFR 1910.147. Among other methods, one feasible and acceptable method to correct this hazard would be to develop and implement a written hazard training program on lockout/tagout.
Recent events (2)
- · I (S) $714.00
- · Z (S) $3000.00
5(a)(1)
- Issued
- May 19, 1993
- Abate by
- Jun 21, 1993
- Penalty
- Initial $3,000 · Current $714 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to electrical shock, burns and/or electrocution: (a) F/V Response: In the engineer space, a breaker panel was missing the door, exposing employees to contact with live electrical parts. The breaker panel contained breakers labeled "20 hp chiller" and "45 hp chiller." This is a 220-volt panel, which had three blue lights installed at the top and all were lit. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the door. (b) F/V Response: In the engineer space, a breaker panel was missing its front, exposing employees to contact with live electrical parts. This cabinet also was missing "knockouts" in the side and bottom. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the cover. (c) F/V Response: In the engine room, a breaker panel with a common center bus bar was missing its cover, exposing employees to live electrical parts. The 220-volt panel was located adjacent to a transformer across from the diesel generator. This panel contained the breakers for the crane and bait freezer. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the cover. (d) F/V Response: In the engine space, a breaker panel attached to storage bins was missing its cover, exposing employees to live electrical parts. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the cover. (e) F/V Response: In the engine room, an open panel box was located along the wall adjacent to the hot water heater. The 220-volt panel was divided into three sections, and a conduit entering the panel from the bottom was broken. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the cover. (f) F/V Response: In the engine room, a 120-volt light switch, adjacent to the hot water heater, was missing the cover plate, exposing employees to live electrical wires. Among other methods, one feasible and acceptable abatement method to correct this hazard is replace the cover. (g) F/V Response: In the engine room, an electrical "J" box, located on the ceiling adjacent to the water line, was missing the cover material in proper knockout covers and lacked conduit and wire strain relief devices, resulting in employees exposure to live electrical parts. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the cover, provide proper knockout cover and conduit. (h) F/V Response: In the engine room, a 220-volt electrical meter, painted blue, was missing the cover to the "J" box, exposing employees to live electrical parts. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the cover. (i) F/V Response: In the engine room, a 120-volt junction box was missing its cover. The junction box was located adjacent to the compressed air expansion track beneath a horizontal stretched member used for storage. Wired into this box was a light switch on a flex cable about 18 inches long. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the cover. (j) F/V Response: In the engine room, exposed 120-volt wires with wire nuts to overhead fan unit. Among other methods, one feasible and acceptable abatement method to correct this hazard is to put wires in the conduit and "J" box. (k) F/V Response: In the engine room, an open "J" box, dangling at the end of flexible conduit, was missing a cover and had wires pulled out, exposing employees to contact with live electrical parts. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the cover. (l) F/V Response: In the freezer space, a 120-volt incandescent light was hanging loose from its box, exposing employees to live electrical parts. Among other methods, one feasible and acceptable abatement method to correct this hazard is reassemble the light fixture.
Recent events (2)
- · I (S) $714.00
- · Z (S) $3000.00
5(a)(1)
- Issued
- May 19, 1993
- Abate by
- Jun 6, 1993
- Penalty
- Initial $1,250 · Current $298 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to cuts, contusions, lacerations, and burns: (a) F/V Response: In the freezer space, a 120-volt incandescent lamp was missing its guard. The fixture was originally equipped with a guard. This exposed employees to the potential of broken glass and exposed live electrical parts. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the guard. (b) F/V Response: In the processing area, a fluorescent light fixture within 6 feet of the floor, directly adjacent to the water hose rack was unguarded. This exposed employees to the potential of broken glass and burns. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the guard.
Recent events (2)
- · I (S) $297.50
- · Z (S) $1250.00
1918.12 A
- Issued
- May 19, 1993
- Abate by
- Jun 21, 1993
- Penalty
- Initial $3,000 · Current $714 Reduced
Recent events (2)
- · I (S) $714.00
- · Z (S) $3000.00
1918.51 B
- Issued
- May 19, 1993
- Abate by
- Jun 21, 1993
- Penalty
- Initial $3,000 · Current $714 Reduced
Recent events (2)
- · I (S) $714.00
- · Z (S) $3000.00
1918.91 B
- Issued
- May 19, 1993
- Abate by
- May 23, 1993
- Penalty
- Initial $1,250 · Current $298 Reduced
Recent events (2)
- · I (S) $297.50
- · Z (S) $1250.00
1918.96 D
- Issued
- May 19, 1993
- Abate by
- Jun 21, 1993
- Penalty
- Initial $750 · Current $179 Reduced
Recent events (2)
- · I (S) $178.50
- · Z (S) $750.00
More inspections at Pankof Fisheries
View Pankof Fisheries's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 109432104.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.