LA BELLE, MO ·
OSHA Inspection: ADM LA BELLE
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ADM LA BELLE in 210 N. 7TH ST., LA BELLE, MO 63447 (NAICS 424510). OSHA activity number 109589382.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADM LA BELLE
- Site address
- 210 N. 7TH ST.
- City
- LA BELLE
- State
- MO
- ZIP
- 63447
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424510
- SIC code (legacy)
- 5153
- Employees
- 2
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- May 15, 2007
- Abate by
- Aug 16, 2007
- Penalty
- Initial $2,125 · Current $1,275 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) At the time of the inspection, employees were using the manually operated manlift to access the upper levels of the elevator. The following deficiencies were noted; 1. The manlift was not periodically maintained and inspected by qualified personnel. 2. The driving machine-brake was not tested with both empty car and rated load in the car. Failure of the elevator would create a fall from elevation. Among other methods, one feasible and acceptable method to abate this hazard is to comply with ASME A17.3 Section 1.5(a)&(b). That standard references the following sections of ASME A17.1 Sections 8.6, 8.7, 8.10, & 8.11. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation.
Recent events (2)
- · I (S) $1275.00
- · Z (S) $2125.00