ST. PETERSBURG, FL —
OSHA Inspection: MARINA PROPERTIES, INC.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of MARINA PROPERTIES, INC. in 1901 PASS-A-GRILLE WAY, ST. PETERSBURG, FL 33706 (NAICS 000000). OSHA activity number 109611491.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARINA PROPERTIES, INC.
- Site address
- 1901 PASS-A-GRILLE WAY
- City
- ST. PETERSBURG
- State
- FL
- ZIP
- 33706
- Mailing
- 2126 1ST AVE., SOUTH, ST. PETERSBURG, FL 33712
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 4493
- Employees
- 7
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 27, 1994
- Abate by
- Oct 31, 1994
- Penalty
- Initial $1,000 · Current $1,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by fragments of plastic pipe used to transport compressed air for the operation of air operated tools and air used for cleaning, in the event the piping ruptures: a. Throughout the maintenance shop and the boat storage area, polyvinyl chloride ( PVC ) plastic pipe was used to transport compressed air in exposed above ground locations, for the operation of air operated tools and air used for cleaning, a practice not recommended by the Plastics Pipe Institute and prohibited by ANSI/ASME B31.8-1986, Gas Transmission and Distribution Piping Systems standard, on or about 9/1/94. Among other methods one feasible and acceptable method to correct this hazard is to replace the PVC piping with a type that is approved for transporting compressed gases in exposed above ground locations, such as iron or steel piping.
1910.23 C01
- Issued
- Sep 27, 1994
- Abate by
- Oct 5, 1994
- Penalty
- Initial $1,000 · Current $1,000
1910.27 B01 II
- Issued
- Sep 27, 1994
- Abate by
- Oct 5, 1994
- Penalty
- Initial $1,000 · Current $1,000
1910.27 B01 III
- Issued
- Sep 27, 1994
- Abate by
- Oct 5, 1994
1903.2 A01
- Issued
- Sep 27, 1994
- Abate by
- Sep 30, 1994
- Penalty
- Initial $2,000 · Current $2,000
1910.303 G02 I
- Issued
- Sep 26, 1994
- Abate by
- Sep 29, 1994
- Penalty
- Initial $1,000 · Current $1,000
More inspections at Marina Properties, INC.
View Marina Properties, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 109611491.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.