FRAMINGHAM, MA ·
OSHA Inspection: MANN INDUSTRIES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MANN INDUSTRIES, INC. in 255 ARLINGTON STREET, FRAMINGHAM, MA 01701 (NAICS 000000). OSHA activity number 109628594.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MANN INDUSTRIES, INC.
- Site address
- 255 ARLINGTON STREET
- City
- FRAMINGHAM
- State
- MA
- ZIP
- 01701
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2295
- Employees
- 74
- Ownership type
- Private (A)
- Industry flags
- Manufacturing safety.
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 22, 1994
- Abate by
- Dec 25, 1994
- Penalty
- Initial $3,000 · Current $3,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) Location: Oven area; On or about 10/10/94 employees were exposed to a fire hazard. The employer did not take adequate precautions against the build-up and ignition of flammable vapors in unit #2 which utilized flammable solvents. Among other methods, acceptable abatements would be to install automatic fast sensing devices to detect and collect flammable vapor levels. The set points for the device should be lowered below the lower explosive level (LEL) and there should be a visual as well as audible alarm system to indicate that the set points have been exceeded. The inspection and calibration of these sensing devices should be done frequently and documented. Install a new drive system to better control the tension of the rollers to reduce solvent build-up. Install an automatic device to prevent the dryer fans from shutting down until the oven temperature is reduced to a safe level. In addition, redesign the oven to eliminate the ignition source of flame and also install a static discharge system to reduce the possibility of sparks. Regular inspection and maintenance of the duct work, dampers, control system and exhaust fans should be conducted and documented on a scheduled basis. Testing for fuel leakage should also be conducted and documented on a regular basis. OR IN THE ALTERNATIVE 29 CFR 1910.106(e)(6)(i): Adequate precautions against the ignition of flammable vapors were not taken: (a) Oven area: The employer did not take adequate precautions against the ignition of flammable vapors from oven #2 containing flammable solvents, exposing employees to fire hazards.s
1910.23 C01
- Issued
- Nov 22, 1994
- Abate by
- Dec 25, 1994
- Penalty
- Initial $1,500 · Current $375 Reduced
Recent events (2)
- · I (S) $375.00
- · Z (S) $1500.00
1910.212 A01
- Issued
- Nov 22, 1994
- Abate by
- Dec 25, 1994
- Penalty
- Initial $1,500 · Current $375 Reduced
Recent events (2)
- · I (S) $375.00
- · Z (S) $1500.00
1910.212 A01
- Issued
- Nov 22, 1994
- Abate by
- Dec 25, 1994
1910.212 A03 II
- Issued
- Nov 22, 1994
- Abate by
- Jan 25, 1995
- Penalty
- Initial $1,500 · Current $375 Reduced
Recent events (2)
- · I (S) $375.00
- · Z (S) $1500.00
1910.219 D01
- Issued
- Nov 22, 1994
- Abate by
- Dec 25, 1994
- Penalty
- Initial $1,500 · Current $375 Reduced
Recent events (2)
- · I (S) $375.00
- · Z (S) $1500.00
1910.219 C04 I
- Issued
- Nov 22, 1994
- Abate by
- Dec 25, 1994
Recent events (2)
- · I (O)
- · Z (O)
More inspections at Mann Industries, INC.
View Mann Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 109628594.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.