Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROSSI PIZZA, INCORPORATED

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of ROSSI PIZZA, INCORPORATED in 228 LINCOLN HIGHWAY, WATERMAN, IL 60556 (NAICS 000000). OSHA activity number 109631176.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rossi Pizza, Incorporated — free Get an email when a new federal OSHA severe-injury report for Rossi Pizza, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
228 LINCOLN HIGHWAY
City
WATERMAN
State
IL
ZIP
60556
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
2038
Employees
40
Ownership type
A
Industry flags
Manufacturing health.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 07 1 instance 15 exposed
Issued
Jan 18, 1991
Abate by
Feb 16, 1991
Penalty
Initial $7,000 · Current $1,000 Reduced
SECTION 5(A)(1) OF THE OCCUAPTIONAL SAFETY AND HEALTH ACT OF 1970: THE
EMPLOYER DID NOT FURNISH EMPLOYMENT AND A PLACE OF EMPLOYMENT WHICH WERE
FREE FROM RECOGNIZED HAZARDS THAT WERE CAUSING OR LIKELY TO CAUSE DEATH
OR SERIOUS PHYSICAL HARM TO EMPLOYEES IN THAT EMPLOYEES WERE EXPOSED TO
THE HAZARD OF DIZZINESS, DIFFICULT BREATHING, LOSS OF CONSCIOUSNESS, AND
ASPHYXIATION WHILE WORKING IN AREA(S) ADJACENT TO THE LIQUID NITROGEN
TUNNEL. LEAKS OF NITROGEN FROM THE LIQUID NITROGEN TUNNEL AND
ASSOCIATED EQUIPMENT INTO THE WORK AREA DISPLACES OXYGEN WHICH MAY
RESULT IN OXYGEN-DEFICIENT ATMOSPHERE(S).
AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO
CORRECT THIS HAZARD IS:
1) MAINTAIN THE NITROGEN TUNNEL AND ASSOCIATED EQUIPMENT SO AS TO AVOID
LEAKS OF NITROGEN INTO THE WORK AREA.
2) PROVIDE SUFFICIENT TEMPERED MAKE-UP AIR AND EXHAUST VENTILATION
SO AS TO MAINTAIN OXYGEN LEVELS IN THE WORK AREA AT OR ABOVE 19.5%.
3) INSTALL OXYGEN METER(S) IN THE WORK AREA TO TEST FOR THE PRESENCE OF
SUFFICIENT OXYGEN (19.5%). THE OXYGEN METER(S) SHALL BE MAINTAINED,
TESTED AND CALIBRATED BY TRAINED INDIVIDUALS. IF OXYGEN LEVELS FALL
BELOW 19.5%, APPROPRIATE ACTION SUCH AS, BUT NOT LIMITED TO,
EVACUATION OF EMPLOYEES, SHUT-DOWN OF THE LIQUID NITROGEN TUNNEL
AND/OR VENTILATING THE WORKPLACE SHALL BE DONE UNTIL SUFFICIENT
LEVELS OF OXYGEN ARE ACHIEVED IN THE WORKPLACE (19.5%-25%). AT NO
TIME SHALL EMPLOYEE(S) BE ALLOWED TO ENTER AND/OR WORK IN AREA(S)
WHERE THE OXYGEN LEVELS ARE UNKNOWN.
Recent events (3)
  • — F (S) $1000.00
  • — R (S) $1000.00
  • — Z (W) $7000.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 109631176.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.