Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRI-CITY ELECTRICAL CONTRACTORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TRI-CITY ELECTRICAL CONTRACTORS, INC. in 13711 S. TAMIAMI TRAIL, SUITE 100, FT. MYERS, FL 33912 (NAICS 000000). OSHA activity number 109714261.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tri-City Electrical Contractors, INC. — free Get an email when a new federal OSHA severe-injury report for Tri-City Electrical Contractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
13711 S. TAMIAMI TRAIL, SUITE 100
City
FT. MYERS
State
FL
ZIP
33912
Mailing
5910 HARTFORD STREET, TAMPA, FL 33619
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
1731
Employees
7
Ownership type
A
Industry flags
Construction safety.

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 3 instances 1 exposed
Issued
Sep 15, 1993
Abate by
Sep 20, 1993
Penalty
Initial $5,000 · Current $2,000 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: the
employer
did not furnish employment and a place of employment which were free from
recognized hazards that were causing or likely to cause death or serious
physical
harm to employees in that employees were exposed to the hazard of being
struck
by the unregulated release of carbon dioxide and/or the related equipment
used
with it:
a)  Outside of the electric room, north of the electric room entry
door,
the cylinder of carbon dioxide was standing upright and unsecured
from
falling over.  The cylinder did not have a valve protection cap in
place
which posed the problem of cylinder, (with 1800 psi or more inside),
becoming a projectile, on or about 6/16/93.
b) Outside of the electric room, north of the electric room, entry
door,
the pressure in the red rubber, SpeedAire hose was not regulated.
The
hose
was deformed and in danger of rupturing.  The working pressure of
the air
hose is 250 psi, the carbon dioxide in the cylinder was 1800 psi or
greater, on or about 6/16/93.
c)  Outside of the electric room, north of the electric room entry
door,
the blow gun was unrestricted with a nozzle pressure in excess of
100 psi,
on or about 6/16/93.
Among others, one feasible and acceptable abatement method to
correct this
hazard is to secure the carbon dioxide cylinder in the upright
position
and install a pressure regulator to the valve.
Recent events (2)
  • — J (S) $2000.00
  • — Z (S) $5000.00

1926.405 A02 III

Serious Gravity 03 1 instance 1 exposed
Issued
Sep 15, 1993
Abate by
Sep 20, 1993
Penalty
Initial $2,500 · Current $1,500 Reduced
Recent events (2)
  • — J (S) $1500.00
  • — Z (S) $2500.00

1926.405 G02 III

Serious Gravity 03 1 instance 1 exposed
Issued
Sep 15, 1993
Abate by
Sep 20, 1993
Recent events (2)
  • — J (S)
  • — Z (S)

1926.20 B01

Other-than-serious Gravity 01 1 instance 7 exposed
Issued
Sep 15, 1993
Abate by
Sep 27, 1993
Recent events (2)
  • — W (O)
  • — Z (O)

1926.403 H

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Sep 15, 1993
Abate by
Sep 27, 1993
Recent events (2)
  • — W (O)
  • — Z (O)

1926.403 I01 I

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Sep 15, 1993
Abate by
Sep 20, 1993
Recent events (2)
  • — W (O)
  • — Z (O)

1926.403 I01 II

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Sep 15, 1993
Abate by
Sep 20, 1993
Recent events (2)
  • — W (O)
  • — Z (O)

1926.405 B02

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Sep 15, 1993
Abate by
Sep 20, 1993
Recent events (2)
  • — W (O)
  • — Z (O)

View Tri-City Electrical Contractors, INC.'s full OSHA safety record →