Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CROWN CORK & SEAL

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CROWN CORK & SEAL in 125 OTTLEY DRIVE, NE, ATLANTA, GA 30324 (NAICS 000000). OSHA activity number 110107216.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Crown Cork & Seal — free Get an email when a new federal OSHA severe-injury report for Crown Cork & Seal is published. One employer, no account, unsubscribe in one click.
Establishment
CROWN CORK & SEAL
Site address
125 OTTLEY DRIVE, NE
City
ATLANTA
State
GA
ZIP
30324
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3411
Employees
185
Ownership type
A
Industry flags
Manufacturing safety.

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 04 3 instances 6 exposed
Issued
Sep 27, 1991
Abate by
Oct 8, 1991
Penalty
Initial $1,625 · Current $1,625
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment and a place of employment which
were free from recognized hazards that were causing or likely to cause
death or serious physical harm to employees in that employees were
exposed to explosion hazard:
(a)  Frequent and regular inspections of Fail-safes on (3) Ross Dual
Flow Ovens are not performed to insure that they are properly
maintained and kept in working order.
Among other methods, one feasible and acceptable abatement method
to correct this hazard is to develop and implement a maintenance
program which includes that all safety devices on ovens to be
inspected at intervals of not less than twice a month by a expecially
appointed, properly instructed employee, and not less than once a
year by representatives of the oven manufacturers.

1910.1001 D02 I

Serious Gravity 05 1 instance 4 exposed
Issued
Sep 27, 1991
Abate by
Sep 30, 1991
Penalty
Initial $2,275 · Current $2,275

1910.22 D01

Other-than-serious 1 instance 1 exposed
Issued
Sep 27, 1991
Abate by
Oct 8, 1991

1910.106 D02 III

Other-than-serious 1 instance 4 exposed
Issued
Sep 27, 1991
Abate by
Oct 8, 1991

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Sep 27, 1991
Abate by
Oct 8, 1991

View Crown Cork & Seal's full OSHA safety record →