Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ENFINGER AUTO RADIATOR SERVICE, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ENFINGER AUTO RADIATOR SERVICE, INC. in 6450 PENSACOLA BLVD., PENSACOLA, FL 32505 (NAICS 000000). OSHA activity number 110136611.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Enfinger Auto Radiator Service, INC. — free Get an email when a new federal OSHA severe-injury report for Enfinger Auto Radiator Service, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6450 PENSACOLA BLVD.
City
PENSACOLA
State
FL
ZIP
32505
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
7539
Employees
13
Ownership type
A
Industry flags
Manufacturing health.

21 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 1 instance 2 exposed
Issued
Oct 10, 1995
Abate by
Oct 18, 1995
Penalty
Initial $340 · Current $340
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:
The employer did not furnish employment and a place of employment
which were free from recognized hazards that were causing or likely
to cause death or serious physical harm to employees in that
employees were exposed to being struck by projected materials:
a.On or about 6/27/95, employees were exposed to the hazard
of being struck or punctured by projectiles from
polyvinyl chloride (PVC) pipe, having a line pressure of
over 100 psig which was used to transport compressed air
for the radiator repairmen.  Fragmentation of the pipe
can occur because of fatigue caused by cold contents, and
or ambient temperatures, non-compatibility of pipe with
its contents, etc.
Among other methods, three feasible and acceptable abatement
methods to correct this hazard are:
1.An Acrylonitrite, Butadiene Styrene (ABS) pipe could be
used.
2.Polyvinyl vinyl chloride pipe (PVC) with that is
completely enclosed in steel pipe covering or casing of
sufficient strength to provide protection from external
damage and deterioration.
3.Metal piping could be used.

1910.22 A01

Serious Gravity 01 1 instance 13 exposed
Issued
Oct 10, 1995
Abate by
Oct 20, 1995
Penalty
Initial $250 · Current $250

1910.151 C

Serious Gravity 03 1 instance 2 exposed
Issued
Oct 10, 1995
Abate by
Nov 13, 1995
Penalty
Initial $430 · Current $430

1910.132 A

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 10, 1995
Abate by
Oct 18, 1995
Penalty
Initial $860 · Current $860

1910.133 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 10, 1995
Abate by
Oct 13, 1995

1910.242 B

Serious Gravity 03 1 instance 2 exposed
Issued
Oct 10, 1995
Abate by
Oct 13, 1995

1910.252 A02 II

Serious Gravity 01 1 instance 13 exposed
Issued
Oct 10, 1995
Abate by
Oct 27, 1995
Penalty
Initial $260 · Current $260

1910.157 G01

Serious Gravity 01 1 instance 13 exposed
Issued
Oct 10, 1995
Abate by
Oct 27, 1995

1910.38 A01

Serious Gravity 01 1 instance 13 exposed
Issued
Oct 10, 1995
Abate by
Oct 27, 1995

1910.1200 E01

Serious Gravity 03 1 instance 7 exposed
Issued
Oct 10, 1995
Abate by
Oct 27, 1995
Penalty
Initial $430 · Current $430

1910.1200 F05 I

Serious Gravity 03 1 instance 7 exposed
Issued
Oct 10, 1995
Abate by
Oct 27, 1995

1910.1200 F05 II

Serious Gravity 03 2 instances 7 exposed
Issued
Oct 10, 1995
Abate by
Oct 27, 1995

1910.1200 G08

Serious Gravity 03 1 instance 13 exposed
Issued
Oct 10, 1995
Abate by
Oct 27, 1995

1910.1200 H01

Serious Gravity 03 13 instances 13 exposed
Issued
Oct 10, 1995
Abate by
Nov 13, 1995

1910.1025 C01

Serious Gravity 03 1 instance 2 exposed
Issued
Oct 10, 1995
Abate by
Feb 15, 1996
Penalty
Initial $430 · Current $430

Hazardous substances 1591

1910.1025 D02

Serious Gravity 03 1 instance 2 exposed
Issued
Oct 10, 1995
Abate by
Feb 15, 1996

Hazardous substances 1591

1910.1025 F01

Serious Gravity 03 1 instance 2 exposed
Issued
Oct 10, 1995
Abate by
Feb 15, 1996

Hazardous substances 1591

1910.1025 I01

Serious Gravity 03 1 instance 2 exposed
Issued
Oct 10, 1995
Abate by
Feb 15, 1996

Hazardous substances 1591

1910.1025 J01 I

Serious Gravity 03 1 instance 2 exposed
Issued
Oct 10, 1995
Abate by
Feb 15, 1996

Hazardous substances 1591

1904.2 A

Other-than-serious Gravity 00 5 instances 13 exposed
Issued
Oct 10, 1995
Abate by
Oct 27, 1995

1910.20 G01 I

Other-than-serious Gravity 01 1 instance 13 exposed
Issued
Oct 10, 1995
Abate by
Oct 27, 1995

View Enfinger Auto Radiator Service, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 110136611.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.