WATERVILLE, OH —
OSHA Inspection: MARIETTA STRUCTURES CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MARIETTA STRUCTURES CORPORATION in PLANT NO.1, 5900 RIVER ROAD, WATERVILLE, OH 43566 (NAICS 000000). OSHA activity number 110295714.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARIETTA STRUCTURES CORPORATION
- Site address
- PLANT NO.1, 5900 RIVER ROAD
- City
- WATERVILLE
- State
- OH
- ZIP
- 43566
- Mailing
- P. O. BOX 653, MARIETTA, OH 45750
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1541
- Employees
- 10
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Sep 5, 1990
- Abate by
- Sep 8, 1990
- Penalty
- Initial $810 · Current $810
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: The hazards of fractures, internal injuries, lacerations and concussions while using a come-a-long with cable and hooks to apply tension to a rolled cone fabricated unit to align its circumference to a closed circle before welding. The hazard was caused when the eye pad weld failed and the cable, hook, and pad eye recoiled into an employee's pelvic area, causing him to fall 4 to 5 feet backward and against the cone on or about July 9, 1990. Among other methods, one or more feasible and acceptable abatement methods to correct this hazard are but not limited to: 1) Grind the red oxide primer paint off of the steel area to be welded to insure a good weld bond. 2) Use the proper welding amperage to match that required for the linear footage of electrode cable to be used. The proper amperage is also important in cases where two dissimilar thicknesses exist and amperage should be matched to the thicker material. In additon, the diameter of the electrode shall be such as to relate to the thickness of the material. 3) Refer to the welding manual for the proper selection of the electro rods to be used for the special project would yield the best results.
More inspections at Marietta Structures Corporation
View Marietta Structures Corporation's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 110295714.