OSHA Inspection: MARIETTA STRUCTURES CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MARIETTA STRUCTURES CORPORATION in PLANT NO.1, 5900 RIVER ROAD, WATERVILLE, OH 43566 (NAICS 000000). OSHA activity number 110295714.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Marietta Structures Corporation — free Get an email when a new federal OSHA severe-injury report for Marietta Structures Corporation is published. One employer, no account, unsubscribe in one click.
Site address
PLANT NO.1, 5900 RIVER ROAD
City
WATERVILLE
State
OH
ZIP
43566
Mailing
P. O. BOX 653, MARIETTA, OH 45750
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1541
Employees
10
Ownership type
A
Industry flags
Construction safety.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 09 1 instance 2 exposed
Issued
Sep 5, 1990
Abate by
Sep 8, 1990
Penalty
Initial $810 · Current $810
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
The hazards of fractures, internal injuries, lacerations and
concussions while using a come-a-long with cable and hooks to
apply tension to a rolled cone fabricated unit to align its
circumference to a closed circle before welding. The hazard
was caused when the eye pad weld failed and the cable, hook,
and pad eye recoiled into an employee's pelvic area, causing
him to fall 4 to 5 feet backward and against the cone on or about
July 9, 1990.
Among other methods, one or more feasible and acceptable abatement
methods to correct this hazard are but not limited to:
1) Grind the red oxide primer paint off of the steel area to be welded
to insure a good weld bond.
2) Use the proper welding amperage to match that required for the linear
footage of electrode cable to be used. The proper amperage is also
important in cases where two dissimilar thicknesses exist and
amperage should be matched to the thicker material. In additon, the
diameter of the electrode shall be such as to relate to the thickness
of the material.
3) Refer to the welding manual for the proper selection of the electro
rods to be used for the special project would yield the best results.