ST. LOUIS, MO —
OSHA Inspection: VITRO SEATING PRODUCTS, INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of VITRO SEATING PRODUCTS, INC. in 201 MADISON STREET, ST. LOUIS, MO 63102 (NAICS 337127). OSHA activity number 110463650.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VITRO SEATING PRODUCTS, INC.
- Site address
- 201 MADISON STREET
- City
- ST. LOUIS
- State
- MO
- ZIP
- 63102
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337127
- SIC code (legacy)
- 2599
- Employees
- 54
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Feb 15, 2006
- Abate by
- Apr 4, 2006
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) At this establishment, basement level; lower section of the freight elevator floor gate was modified with a fabricated metal hinged section(s), measuring a total height of (29") twenty-nine inches that was added onto the existing wood section of the gate on the bottom of the hoist-way entrance. The gate addition was added on to eliminate the floor opening hazard, but was not equipped with hoistway interlocks on the vertical outside gate to disable the freight elevator from operating. While ultimate responsibility for correcting the hazard rests with the employer, given his/her superior knowledge of the work place, feasible and acceptable methods to correct this hazard, among others, are: 1. Follow guidelines listed in American Standards Institute (ANSI) A17.1 2004 - Safety Code for Elevators. Section 110 - Protection of Hoistway-Landing Openings. 2. Follow guidelines listed in American Standards Institute (ANSI) A17.1 2004 - Safety Code for Elevators. Section 111 - Hoistway-Door Locking Devices, Car Door or Gate Electric Contacts, Hoistway Access Switches, and Elevator Parking Devices. 3. Follow guidelines listed in American Standards Institute (ANSI) A17.3 2004 - Safety Code For Existing Elevators and Escalators. Section 4.7 Operating Devices and Control Equipment, paragraph 4.7.4 Electrical Protective Devices. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations(s).
Recent events (2)
- — J (S) $1500.00
- — Z (S) $1500.00
More inspections at Vitro Seating Products, INC.
View Vitro Seating Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337127)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 110463650.