Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VITRO SEATING PRODUCTS, INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of VITRO SEATING PRODUCTS, INC. in 201 MADISON STREET, ST. LOUIS, MO 63102 (NAICS 337127). OSHA activity number 110463650.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vitro Seating Products, INC. — free Get an email when a new federal OSHA severe-injury report for Vitro Seating Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
201 MADISON STREET
City
ST. LOUIS
State
MO
ZIP
63102
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337127
SIC code (legacy)
2599
Employees
54
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Deleted Serious Gravity 03 1 instance 1 exposed
Issued
Feb 15, 2006
Abate by
Apr 4, 2006
Penalty
Initial $1,500 · Current $1,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to:
a) At this establishment, basement level; lower section of the freight
elevator floor gate
was modified with a fabricated metal hinged section(s), measuring a total
height of (29")
twenty-nine inches that was added onto the existing wood section of the
gate on the
bottom of the hoist-way entrance. The gate addition was added on to
eliminate the floor
opening hazard, but was not equipped with hoistway interlocks on the
vertical outside
gate to disable the freight elevator from operating.
While ultimate responsibility for correcting the hazard rests with the
employer, given his/her
superior knowledge of the work place, feasible and acceptable methods to
correct
this hazard,
among others, are:
1. Follow guidelines listed in American Standards Institute (ANSI) A17.1
2004 - Safety Code
for Elevators. Section 110 - Protection of Hoistway-Landing Openings.
2. Follow guidelines listed in American Standards Institute (ANSI) A17.1
2004 - Safety Code
for Elevators. Section 111 - Hoistway-Door Locking Devices, Car Door or
Gate Electric
Contacts, Hoistway Access Switches, and Elevator Parking Devices.
3. Follow guidelines listed in American Standards Institute (ANSI) A17.3
2004 - Safety Code
For Existing Elevators and Escalators. Section 4.7 Operating Devices and
Control Equipment,
paragraph 4.7.4 Electrical Protective Devices.
Abatement certification and abatement documentation is required for this
violation.  The
documentation should include written verification of abatement, applicable
measurements
or monitoring results, and photographs or videos which you believe will be
helpful.  The
abatement certification sheet is enclosed with the citations(s).
Recent events (2)
  • — J (S) $1500.00
  • — Z (S) $1500.00

View Vitro Seating Products, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 110463650.