SPRINGFIELD, MA —
OSHA Inspection: DANAHER TOOL GROUP
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DANAHER TOOL GROUP in 116 WASON AVE., SPRINGFIELD, MA 01107 (NAICS 000000). OSHA activity number 112889951.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DANAHER TOOL GROUP
- Site address
- 116 WASON AVE.
- City
- SPRINGFIELD
- State
- MA
- ZIP
- 01107
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3423
- Employees
- 326
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
23 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
- Penalty
- Initial $955 · Current $475 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the unexpected release of the loader bucket and/or its contents due to rope failure: HEAT TREAT: EMPLOYEES WERE EXPOSED TO THE HAZARD OF BEING STRUCK BY THE LOADER HOIST BUCKET AND/OR ITS CONTENTS AND/OR BEING STRUCK BY THE WIRE ROPE ITSELF WHILE OPERATING THE LOADER HOIST PROVIDED ON THE NORTH AND SOUTH END WHEELABRATORS DUE TO THE IMPROPER INSTALLATION AND MAINTENANCE OF THE WIRE ROPE. ONE FEASIBLE AND ACCEPTABLE METHOD TO CORRECT THE HAZARD, AMONG OTHERS, IS TO: 1.FOLLOW THE MANUFACTURER'S GUIDELINES AND/OR ESTABLISHED INDUSTRY GUIDELINES REGARDING THE INSTALLATION OF THE LOADER HOIST COMPONENTS. 2.IMPLEMENT A PROGRAM OF REGULAR, DOCUMENTED INSPECTIONS OF THE LOADER HOIST COMPONENTS AND PERFORM MAINTENANCE AS INDICATED BY THE INSPECTIONS.
Recent events (2)
- — A (S) $475.00
- — Z (S) $955.00
1910.212 A01
- Issued
- Feb 11, 1997
- Abate by
- Mar 31, 1997
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (2)
- — A (S) $750.00
- — Z (S) $1500.00
1910.213 H01
- Issued
- Feb 11, 1997
- Abate by
- Mar 31, 1997
- Penalty
- Initial $565 · Current $565
1910.215 A02
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
- Penalty
- Initial $955 · Current $475 Reduced
Recent events (2)
- — A (S) $475.00
- — Z (S) $955.00
1910.215 A04
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
Recent events (2)
- — A (S)
- — Z (S)
1910.215 B03
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
1910.215 B09
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
1910.217 B07 VA
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
- Penalty
- Initial $955 · Current $480 Reduced
Recent events (2)
- — A (S) $480.00
- — Z (S) $955.00
1910.217 B07 VC
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
1910.217 C02 IA
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
Recent events (2)
- — A (S)
- — Z (S)
1910.217 C03 VIII
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
1910.304 F05 V
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
- Penalty
- Initial $955 · Current $475 Reduced
Recent events (2)
- — A (S) $475.00
- — Z (S) $955.00
1910.305 B02
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
- Penalty
- Initial $955 · Current $480 Reduced
Recent events (2)
- — A (S) $480.00
- — Z (S) $955.00
1910.305 G01 I
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
1910.305 G02 III
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
1910.24 B
- Issued
- Feb 11, 1997
- Abate by
- Mar 31, 1997
Recent events (2)
- — A (O)
- — Z (O)
1910.147 C05 I
- Issued
- Feb 11, 1997
- Abate by
- Mar 31, 1997
1910.147 C05 IID
- Issued
- Feb 11, 1997
- Abate by
- Mar 31, 1997
1910.213 B03
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
1910.217 B08 III
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
1910.219 E01 I
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
1910.305 B01
- Issued
- Feb 11, 1997
- Abate by
- Feb 14, 1997
1910.305 G01 III
- Issued
- Feb 11, 1997
- Abate by
- Mar 31, 1997
More inspections at Danaher Tool Group
View Danaher Tool Group's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in MA
Source